Phoenix R150 LGR Owner's Manual

Phoenix R150 LGR Owner's Manual

Lgr dehumidifier

Advertisement

Owner's Manual — Phoenix R150 LGR Dehumidifier
The Phoenix R150 LGR (low grain refrigerant) packs Large
dehumidifier performance into the smallest, lightest, and
most portable chassis in the restoration market. The R150
combines Phoenix innovation, technical expertise, and
proven durability into a unit that will remove more water,
produce higher grain depression, and dry structures faster
than competitive dehumidifiers.
The Phoenix R150 LGR Dehumidifier
LGR Capacity - Removes moisture even in dry conditions
for deep drying.
Energy Efficiency - Removes 75 pints at AHAM while
drawing only 5.5 amps.
Patented Bypass Technology - Extends operating range
to 110°F
150 CFM - Optimized process air speeds drying and
provides static pressures for ducting.
More Grain Depression - Drier air from an LGR gets your
jobs done quicker.
Focused Airflow - Patented Focused outlet directs air
downward across the wet surface.
Outlet Ducting - 10" exhaust.
Plastic Housing - Rugged roto-molded housing resists
dents and scratches.
Solid State Controls - Easy to read and operate.
Protected Condensate Hose - Recessed hose cannot
catch or be damaged on obstructions.
Rotating Handle - A heavy-duty rotating handle for ease
of transport and storage.
Recessed 12" Wheels - Allows greater maneuverability
on the job site and efficient storage. Rolls over obstacles
with ease.
Pleated Media Air Filter - Standard MERV-8 filtration
Storage - Front pocket for cord and hose storage
Lighted cord - Easy to determine power to the unit.
Specifications subject to change without notice.
Toll-Free 1-800-533-7533
4201 Lien Rd. • Madison, WI 53704
Installation, Operation & Service Instructions
Read and Save These Instructions
Optional MERV-11
In addition to the performance benefits, patented bypass
technology and tough compact size, are the ducting options,
pleated media filter and energy efficient operation. The
R150 is the latest member of the Phoenix line of LGR
dehumidifiers; the most effective and versatile drying devices
made.
Patented
BYPASS
Phoenix R150
Part No. 4031250
Patent 7,246,503
7,281,389
7,540,166
1
www.UsePhoenix.com • sales@UsePhoenix.com
TS-715
05/14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R150 LGR and is the answer not in the manual?

Questions and answers

Summary of Contents for Phoenix R150 LGR

  • Page 1: Introduction

    The combines Phoenix innovation, technical expertise, and R150 is the latest member of the Phoenix line of LGR proven durability into a unit that will remove more water, dehumidifiers; the most effective and versatile drying devices produce higher grain depression, and dry structures faster made.
  • Page 2: Table Of Contents

    It may be tipped onto its INTERRUPTER. handle and back for loading and moving by hand. • DO NOT use the Phoenix R150 as a bench or table. • It must always be used in the upright position. Toll-Free 1-800-533-7533...
  • Page 3: Electrical Requirements

    3.2 Electrical Requirements 3.6 POWER Button The Phoenix R150 plugs into a common grounded outlet on a 15 amp circuit. It draws 5.5 amps at 80°F, 60% RH. If used in a wet area, a ground fault interrupter (GFI) is required. If...
  • Page 4: Maintenance

    4.1 Air Filter air conditioner’s to remove heat and moisture from incoming The Phoenix R150 is equipped with a pleated media air filter air and to add heat to the air that is discharged. that must be checked regularly. The standard filter is a MERV- Hot, high pressure refrigerant gas is routed from the 8 high efficiency filter.
  • Page 5: Troubleshooting

    Unit runs but does not pump water. 5.2 Troubleshooting 1. Hose kinked or plugged No dehumidification, neither hour meter display nor compressor run and POWER button does not turn ON. 2. Pump motor defective 1. Unit unplugged or no power to outlet 3.
  • Page 6: Air Mover

    5.3 Air Mover 5.5 Condensate Pump The motorized impeller has a PSC motor and internal thermal The internal condensate pump removes water that overload protection. If defective, the complete assembly must collects in the reservoir. be replaced. To replace the condensate pump: 1.
  • Page 7: Wiring Diagram

    7 Wiring Diagram BLK-5 PLUG GRN-14 GRN-13 BRN-12 MOTOR PUMP FAN BLK-16 1 - LINE CONTROL WHT-2 2 - NEUT BOARD WHT-7 BLK-3 LEVEL BLU-8 BLK-11 3 - COMP SWITCH THERMISTOR BLK-4 SAFETY BLK-15 PUMP YEL-10 WHT-6 FLOAT RED-9 WHT-7 P/N 4031273 REV C Wiring diagram Toll-Free 1-800-533-7533...
  • Page 8: Service Parts

    8 Service Parts Items listed are not shown Description Part No. Item Description Part No. Hose (1/4” ID x 33’ long) 4024916 Top Cover 4031258 Coupling Body, 1/4” Tube 4024910 Filter, 12” x 12” x 1” MERV 7 4026315 Coupling Insert, 1/4” Tube 4027277 Impeller, Air Mover 4034477...
  • Page 9: Warranty

    (but all warranty periods will be extended by the period of time, if any, that the Phoenix R150 Dehumidifier is out of service while awaiting covered warranty service).

This manual is also suitable for:

R150

Table of Contents