Phoenix R200 LGR Owner's Manual

Phoenix R200 LGR Owner's Manual

Compact, energy efficient lgr dehumidifier

Advertisement

Owner's Manual — Phoenix R200 LGR Dehumidifier
The Phoenix R200 is a compact, energy efficient LGR
dehumidifier that removes 125 pints per day (AHAM) while
drawing only 8.3 amps of electricity. The R200 outperforms
larger competitive dehumidifiers by removing more water,
providing larger grain depression and consuming less power.
The proven LGR design is surrounded by a durable roto-
molded high impact plastic to create a dehumidifier that is
smaller and lighter than competitive units.
The Phoenix R200 LGR Dehumidifier
Patented Bypass Technology - Increased performance over a
wide temperature range.
R-410A Refrigerant - The Phoenix R200 comes charged
with R-410A refrigerant.
Capacity - The Phoenix R200 removes 125 pints per day at
AHAM (80°F/60%RH).
Energy Efficiency - Draws only 8.3 amps and removes 5.2
pints/kWh.
Compact Design - Smaller, 20"x20"x33.5", and only 105 lbs.
Motorized Impeller - 325 CFM; Faster drying and superior
static pressure for ducting.
More Grain Depression - Drier air from an LGR finishes jobs
quicker versus a conventional refrigerant dehumidifier.
Focused Airflow - Patent focused outlet directs air downward
across the wet surface.
Multiple Ducting Options - 12" intake, 10" exhaust.
Plastic Housing - Rugged roto-molded housing.
Solid State Controls - Easy to read and operate.
Protected Condensate Hose - Located under the top cover.
Quick connect, cannot catch or be damaged on obstructions.
Telescoping Handle - A heavy-duty retractable handle for ease
of transport and reduces space for storage and stacking.
Recessed 12" Wheels - Allows greater maneuverability on the
job site and efficient storage. Rolls over obstacles with ease.
Pleated Media Air Filter - A 12"x12"x1" MERV-11 filter is
standard.
Stacking/Nesting - Reduces space for ease of stacking and
storage.
Specifications subject to change without notice.
Toll-Free 1-800-533-7533
4201 Lien Rd. • Madison, WI 53704
Installation, Operation & Service Instructions
Read and Save These Instructions
In addition to the performance benefits and compact size,
the R200 has patented bypass technology, increased
airflow, multiple ducting options, and a pleated media
filter. The R200 is the latest member of the Phoenix line of
LGR dehumidifiers; the most effective and versatile drying
devices made.
Patented
BYPASS
Phoenix R200
Part No. 4027000
Patent 7,246,503
7,281,389
7,540,166
1
www.UsePhoenix.com • sales@UsePhoenix.com
TS-391
09/13

Advertisement

Table of Contents
loading

Summary of Contents for Phoenix R200 LGR

  • Page 1: Introduction

    The R200 is the latest member of the Phoenix line of providing larger grain depression and consuming less power. LGR dehumidifiers; the most effective and versatile drying The proven LGR design is surrounded by a durable roto- devices made.
  • Page 2: Table Of Contents

    • If used in a wet area, plug it into a GROUND FAULT INTERRUPTER. 3.1 Transporting • DO NOT use the Phoenix R200 as a bench or table. The Phoenix R200 features a high impact roto-molded • It must always be used in the upright position.
  • Page 3: Electrical Requirements

    15 minutes before the final purge. outward to overlap the outside of the collar. The duct and collar may then be quickly attached to the Phoenix R200 by snapping the collar over the four plastic exhaust tabs.
  • Page 4: Defrost Light

    CAUTION: Do not operate unit without the front housing in 4.1 Air Filter place. The Phoenix R200 is equipped with a pleated media air filter that must be checked regularly. The standard filter is 5.1 Technical Description a MERV-11 high efficiency filter. Operating the unit with The Phoenix R200 uses a refrigeration system similar to a dirty filter will reduce the dehumidifier’s capacity and...
  • Page 5: Troubleshooting

    3. Loose connection in compressor circuit 4. Defective compressor overload 5. Defective compressor 6. Defective relay 7. Upper housing is not sealed to lower housing No dehumidification, air mover runs but compressor does not. 1. Bad connection in compressor circuit 2.
  • Page 6: Air Mover

    5.5 Condensate Pump Evaporator coil frosted continuously, low dehumidifying capacity. The internal condensate pump removes water that collects 1. Defrost thermistor loose or defective in the reservoir. 2. Low refrigerant charge To replace the condensate pump: 3. Dirty air filter or restricted air flow 1.
  • Page 7: Options & Accessories

    6 Options & Accessories 4024750 Intake Flex Duct 12” x 25” Metallize Polyester 4024935 Lay-Flat Duct 10” Round x 250’ Roll To order, contact Therma-Stor LLC at 1-800-533-7533. 7 Wiring Diagram THERMISTOR BLU-14 WHT-2 BLK-4 CONTROL BOARD LEVEL COMPRESSOR SWITCH CONDENSATE PUMP BLU-18 4026354 C...
  • Page 8: Parts List

    8 Service Parts Item Description Part No. Item Description Part No. Top Cover 4026977 Coupling Body, 1/4” Tube 4026306 Top Cover Catch 4026979 Coupling Insert, 1/4” Tube 4026986 Top Cover Hinge 4026978 Cord 4032315 Hex Bolts, 1/4”–20 x 4” 4 1154019 Control Board 4026763...
  • Page 9: Warranty

    (but all warranty periods will be extended by the period of time, if any, that the Phoenix R200 Dehumidifier is out of service while awaiting covered warranty service).

This manual is also suitable for:

R200

Table of Contents