Mira Elevate Installation And User Manual page 24

Electric shower
Table of Contents

Advertisement

Malfunction
No water or very low flow
rate.
water leaks from the
bottom of the case near
the outlet, and there is
no flow from the handset.
Cause
the handset sprayplate
is blocked.
the incoming water
supply stop valves, or
the appliance isolating
valve is closed.
the hose or handset is
blocked.
Insufficient water supply
pressure.
the heater tank is
excessively scaled.
the pilot valve is faulty.
The inlet filter is blocked.
the power is off at the
double pole switch.
the fuse is blown or the
McB/rcD has been
tripped, indicating a
possible electrical fault.
the pressure relief valve
in the tank has been
triggered (the shower
has a pressure relief
valve assembly that
works to reduce the
damage if the outlet is
blocked or the unit is
frozen).
when the relief valve
operates a small rubber
ball is ejected.
4
Remedy
clean the handset
sprayplate.
open the stop/isolating
valve completely.
clear the blockage or
replace the hose or
handset.
contact the local water
authority.
replace the heater tank.
Replace the flow
regulator assembly.
Clean the inlet filter.
switch on the power at
the double pole switch.
renew the fuse or reset
the McB/rcD. if the
fault persists contact
customer services.
resolve the blocked
outlet, and replace the
tank assembly.
reset the relief valve
assembly. if the fault
persists, contact
customer services.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents