the trouble shooting information table below gives details on probable causes
and remedies should difficulties be encountered whilst the shower is in operation.
Warning! there are no user serviceable components beneath the cover of the
appliance.
onLy a CoMPeTenT TRaDesPeRson sHoULD ReMoVe THe FRonT CoVeR!
Malfunction
shower is too hot during
the summer.
shower is too hot.
turning the temperature
knob does not affect the
water temperature.
the water continues to
flow when the double
pole switch is turned off.
No water or very low flow
rate.

FaULT DIagnosIs

Cause
the incoming water is
warmer in the summer,
so the shower power
setting is too high.
the handset sprayplate
is blocked.
the handset sprayplate
is blocked.
Broken diaphragm.
the handset sprayplate
is blocked.
the incoming water
supply stop valves, or
the appliance isolating
valve is closed.
the hose or handset is
blocked.
the power is off at the
double pole switch.
the fuse is blown or the
McB/rcD has been
tripped, indicating a
possible electrical fault.

Remedy
turn the power knob to
Medium
and adjust the
temperature knob until
the desired temperature
is reached.
regularly clean the
handset sprayplate.
remove and clean the
handset sprayplate. if the
fault persists, contact the
shower installer.
contact your installer to
replace the flow valve
assembly.
clean the handset
sprayplate.
open the stop/isolating
valve completely.
clear the blockage or
replace the hose or
handset.
switch on the power at
the double pole switch.
renew the fuse or reset
the McB/rcD. if the
fault persists contact the
shower installer.