Install Canister Air Cleaner (Kohler 26 Hp Efi Only); Install Motion Control Levers - Exmark Laser Z Operator's Manual

Laser z series
Hide thumbs Also See for Laser Z:
Table of Contents

Advertisement

3.6 INSTALL CANISTER AIR CLEANER. (Kohler 26 HP EFI units only)
a) Remove air cleaner (with bracket attached) from crate. Keep air cleaner and
mounting bracket together.
b) Remove the top two valve cover mounting screws from both left and right side
engine valve covers. Keep screws for re-attaching air cleaner.
c) Position the air cleaner assembly over the engine, aligning air cleaner bracket
holes with top holes in the valve covers. Reinstall valve cover screws through air
cleaner bracket and torque to 70 in. lb. (4.9 N-m).
d) Remove plastic plugs from air intake elbow on engine and air cleaner hose.
Adjust the air cleaner and hose as required and connect intake hose to air
cleaner outlet. Position and tighten the two hose clamps to secure the hose
connections.
e) Secure air cleaner by tightening the tensioning bolt and spring assembly until
ends of clamp are approximately ½" (12.7 mm) apart.
f) Rotate the air intake elbow as needed to create enough clearance between the
filter minder and the oil filler cap to remove and replace the oil filler cap easily.
See Figure 3.
NOTE: The filter minder must clear the lift lug. If necessary, bend the lift lug
towards the back of the machine to gain clearance for the filter minder.

3.7 INSTALL MOTION CONTROL LEVERS.

3.7.1
Loosen and remove the two (2) 3/8" x 1" bolts and spring disc washers which
attach the motion control levers to the control arm shafts for shipping and the
two (2) 3/8" x 1" bolts and spring disc washers which are screwed into the
control arm shafts.
a)
Install the left motion control lever onto the control arm shaft (See Fig.4) on the
left side of the console. Place the lever (with the mounting plate towards the
rear) on the outside of the control arm shaft and secure with the bolts and
washers. Position the lever so the bolts are in the center of the slots on the
lever mounting plate and tighten until snug. Repeat on opposite side of unit.
If the levers do not align with each other, when in the neutral position, (See
Fig. 5) loosen the hardware and make the appropriate adjustment by
sliding/tilting the lever(s) forward or backward until properly aligned and tighten
hardware.
FIG. 3