The Model 24SII DES will respond with:
Stop/Restart Output upon Receiving of XON/XOFF ? (Y/N):
XON/XOFF Sent Based on buffer Full/Empty Condition ? (Y/N):
The first question addresses XON/XOFF flow control in the transmit
data direction. The second question addresses XON/XOFF flow
control in the receive data direction. You should then enter "Y" to
enable XON/XOFF or "N" to disable XON/XOFF in the respective
directions. For example, if you entered "N" in response to the transmit
direction and "Y" in response to the receive direction, the Model 24SII
DES will respond with:
Bidirectional
---------------------------------------------------
| Port |
Baud | Word | Stop |Parity|
|
|
Rate | Size | Bits |
---------------------------------------------------
|
2
|
38400|
--------------------------------------------------
Exit/Save......1
Set Baud Rate..2
Set Word Size..3
Enter Request :
If there are no other changes for this port, send "1" (Exit/Save), and
the Model 24SII DES will respond with:
Bidirectional
---------------------------------------------------
| Port |
Baud | Word | Stop |Parity|
|
|
Rate | Size | Bits |
---------------------------------------------------
|
1
|
|
2
|
38400|
|
3
|
|
4
|
--------------------------------------------------
Enter
Port Number (ENTER=Exit) :
8
|
1
|None
Set Stop Bits.....4
Set Parity........5
Set XON/XOFF......6
9600|
8
|
1
|None
8
|
1
|None
9600|
8
|
1
|None
9600|
8
|
1
|None
Xon / Xoff |
| Xmit | Recv |
|
Off | On
|
Xon / Xoff |
| Xmit | Recv |
|
Off | Off
|
|
Off | On
|
|
Off | Off
|
|
Off | Off
|