Removal of BioClip Plug

To change a Combi unit from the BioClip function to a
cutting unit with rear ejection, remove the BioClip plug,
which is located under the unit.
1. Put the unit in the service position. See "The
Cutting Unit's Service Position" on page 101.
2. Remove the screws holding the BioClip plug, and
remove the plug.
Tip: Fit the fully threaded screws
M8x15 mm in the screw holes to protect the threads.
3. Return the unit to the normal position.
Fit the BioClip plug in the reverse order.