Removal of BioClip Plug

To change a Combi unit from the BioClip function to a
cutting unit with rear ejection, remove the BioClip plug,
which is located under the unit, attached with three
screws.
1.
Put the unit in service position, see "The cutting
unit's service position" on page 51.
2.
Remove the three screws holding the BioClip plug,
and remove the plug.
Tip: Fit three full-thread screws M8x15 mm in the
screw holes to protect the threads.
3.
Return the unit to the normal position.
Fit the BioClip plug in the reverse order.