Download Print this page

GE PNSF39Z01 Owner's Manual page 16

Profile performance series water softening system

Advertisement

About the water softening system.
Service: Manually Initiated Electronic Diagnostic
RECHARGE
WATER MANAGEMENT SYSTEM
16
This display segment (
B
chart, indicates an open POSITION switch. The
other indicates a closed switch. Use the TOUCH or
HOLD button to manually advance the valve into each
cycle and check correct switch operation.
CORRECT SWITCH
DISPLAYS
Press the DATA button again. This diagnostic display
2
shows the total number of recharges (top) since the
timer was connected to electrical power.
The number of days since the timer was connected to
electrical power is shown in the bottom part of the
display. If over 1999 days, a (x10) indicator shows,
x 10
DAY
meaning you must multiply the number shown by 10.
Press DATA once again to return the present time to
3
the display.
), in the following
VALVE CYCLE STATUS
Valve in service, fill, brining,
backwash or rinse position.
Valve rotating from one
position to another.

Hide quick links:

Advertisement

loading