Table of Contents

Advertisement

Available languages

Available languages

Safety Information . . . . . . . . . . . . . . . . . . . . 2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 4
About the Softener . . . . . . . . . . . . . . . . . . . . 5
Before you Start . . . . . . . . . . . . . . . . . . . . . . . 8
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Installation Requirements . . . . . . . . . . 9-11
Installation Instructions . . . . . . . . . . . 12-16
Programming the Softener . . . . . . . . 17-22
Care and Cleaning . . . . . . . . . . . . . . . . .23, 24
Routine Maintenance . . . . . . . . . . . . . . . . . 25
Before you call for Service . . . . . . . . . 26-29
Exploded View/Parts List . . . . . . . . . . 32-35
Warranty . . . . . . . . . . . . . . . . . . . . . . . . .36, 37
Systems tested and certified by NSF International against
NSF/ANSI Standard 42 for the reduction of chlorine taste and
odor, and NSF/ANSI Standard 44 for the chemical reduction
claims specified on page 3, and certified to NSF/ANSI 372.
Systems Tested and Certified by the Water Quality Association
against CSA B483.1.
R
C
USA
If you have any questions or concerns when installing or maintaining your
water softener, call our toll free number at 800-952-5039 (US) or 866-777-7627
(Canada), or visit www.geappliances.com. When you call, please be prepared
to provide the model and serial number of your product. This information can
be found on the rating decal located on the rim under the salt cover.
GEAppliances.com
Owner's Manual &
Installation Instructions
Models GXMH31H
Write the model and serial
numbers here:
Model # ________________
Serial # _________________
To find these numbers, lift
the cover and look on the rim
below the control panel.
7343475
49-50295 12-14 GE

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for GE GXMH31H

  • Page 1: Table Of Contents

    About the Softener ....5 Models GXMH31H Before you Start ..... . . 8 Dimensions .
  • Page 2: Safety Information

    IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. SAFETY PRECAUTIONS WARNING! For your safety, the information in this manual must be followed to minimize the risk of electric shock, property damage or personal injury. DANGER: WARNING: Do not use with water Electric Shock Hazard: that is microbiologically unsafe or of unknown Install metal ground clamp to metal house...
  • Page 3: Specifications

    Specifications and Performance Claims. This model is efficiency rated. The efficiency rating is valid only at the minimum stated salt dose. The softener has a demand initiated regeneration (D.I.R) feature that complies with specific performance specifications intended to minimize the amount of regenerant brine and water used in its operation. The softener has a rated salt efficiency of not less than 4,000 grains of total hardness exchange per pound of salt (based on sodium chloride), and shall not deliver more salt than its listed rating or be operated at a sustained maximum service flow rate greater than its listed rating.
  • Page 4 Specifications and Performance Claims. Model GXMH31H Rated Capacity* (Grains@ Salt Dose) 11,000 @ 2.6 lbs 24,700 @ 7.8 lbs. 31,100 @ 13.4 lbs. 4,240 @ 2.6 lbs. Water used during Regeneration (gallons/grains) 5.0 /1000 Total Water Used per Regeneration @ Maximum Salt Dose 54.7 gallons...
  • Page 5 About the water softener system. The GE Hybrid Water Softener has been designed the bath and shower which will reduce chlorine’s with two different types of media, a high quality aesthetic effect on your skin and hair, and at every media that reduces tastes and odors and a high bathroom sink for brushing your teeth.
  • Page 6 About the water softener system. NORMAL OPERATION, CONTROL DISPLAYS During normal operation, the present time of day and AM or PM and DAYS TO EMPTY show in the control display area. The system will automatically recharge at the preset recharge time as needed. FEATURE: OPTIONAL RECHARGE CONTROLS RECHARGE TONIGHT Touch (do not hold) the RECHARGE button.
  • Page 7 In these conditions, you brown as air oxidizes the iron. This usually occurs may wish to consider purchasing a GE point-of- in 15 to 30 minutes. entry household filtration system with a chlorine When using the softener to reduce Ferrous (clear reducing filter.
  • Page 8: Before You Start

    Before you start. BEFORE YOU START The water softener requires a minimum water flow of 3 gallons per minute at the inlet. Maximum allowable inlet water pressure is 125 psi. If daytime pressure is over 80 psi, nighttime pressure may exceed the maximum.
  • Page 9: Dimensions

    Installation Requirements. LOCATION REQUIREMENTS DO NOT RUN HOT WATER THROUGH THE SOFTENER. Temperature of water passing Consider all of the following when selecting an through the softener must be less than 120° F. installation location for the water softener. Avoid installing in direct sunlight. Excessive sun Do not locate the water softener where freezing heat may cause distortion or other damage to temperatures occur.
  • Page 10 Installation Requirements. PLUMBING CODES VALVE DRAIN REQUIREMENTS All plumbing must be completed in accordance Using the flexible drain hose (included) (see Figure with national, state and local plumbing codes. 2), measure and cut to the length needed. Flexible drain hose is not allowed in all localities (check In the state of Massachusetts: The Commonwealth your plumbing codes).
  • Page 11 Installation Requirements. INLET/OUTLET PLUMBING REQUIREMENTS 3-VALVE BYPASS SYSTEM Always install either a single bypass valve For soft water service: Open the inlet and outlet (provided),as shown in Figure 4, or, if desired, parts valves and close the bypass valve. for a 3 valve bypass system (not included) can be To bypass the softener and send hard water to purchased and assembled, as shown in Figure 5.
  • Page 12: Installation Instructions

    Installation Instructions. TYPICAL INSTALLATION Ground Hard Water Main Water Pipe Conditioned Clamp to Outside Water Faucets Pipe Incoming- Hard Water Ground Clamp Clips 1” NPT Sweat Cover Adaptor (not Plug-in included) Bypass Valve Transformer Assembly 1” NPT Threaded Adaptor Outlet O-ring Controller Inlet...
  • Page 13 Installation Instructions. TURN OFF WATER SUPPLY 1. Close the main water supply valve, located near Salt the well pump or water meter. Cover Nozzle Venturi Assembly 2. Open all faucets to drain all water from house pipes. Brinewell Nut - Ferrule NOTE: Be sure not to drain water from the water Cover heater, as damage to the water heater elements...
  • Page 14 Installation Instructions. COMPLETE INLET AND OUTLET PLUMBING INSTALL VALVE DRAIN HOSE WARNING! 1. Measure and connect the 3/8”drain line (provided) to the water softener valve drain ELECTRICAL SHOCK HAZARD: fitting. Use a hose clamp to hold the hose in Install metal ground clamp to metal house place.
  • Page 15 Installation Instructions. RINSE OUT CARBON FINES 9. Let the softener complete the backwash and fast rinse cycles (takes about 20 minutes). Small particles of carbon filtration material are When the regeneration ends, the softener’s generated during manufacturing and shipping. valve returns to the service position. These particles will exit the media tank with the first water that flows through the softener.
  • Page 16: Installation Instructions

    Installation Instructions. ADD WATER AND SALT TO THE SALT SANITIZE THE WATER SOFTENER / SANITIZE STORAGE TANK AFTER SERVICE 1. Open salt hole cover, remove the brinewell cover WARNING! and pour about 3 oz. (6 tablespoons) of household EXCESSIVE WEIGHT HAZARD: bleach into the softener brinewell.
  • Page 17: Programming The Water Softener

    Programming the Water Softener. When the transformer is plugged into the SET TIME OF DAY electrical outlet, a model code and test number 1. Press MODE/SET button until the arrow (example: J3.4 & H31) are shown in the display. points to CLOCK. Then, “12:00 PM”...
  • Page 18 Programming the Water Softener. SET WATER HARDNESS NUMBER SET RECHARGE (STARTING) TIME 1. Press the MODE/SET button until the arrow 1. Press the MODE/SET button until the arrow points to HARDNESS. A flashing 25 will appear points to RECHARGE. in the display. Salt Level Salt Level Clock...
  • Page 19 Programming the Water Softener. SET SALT LEVEL DAYS TO EMPTY 1. Press the MODE/SET button until the arrow The words DAYS TO EMPTY and a number are points to SALT LEVEL. shown in the lower half of the display. This information is shown in the normal run display.
  • Page 20 Programming the Water Softener. OPTIONAL CONTROL SETTINGS BACKWASH AND FAST RINSE The controller display has several options and If you experience salty tasting water after features. regeneration, you may need to increase the backwash and fast rinse times. The cycle times LOW SALT ALARM during regenerations are determined by the The LOW SALT ALARM,...
  • Page 21 Programming the Water Softener. FEATURE: OTHER DATA DISPLAY RESETTING TO FACTORY DEFAULT These models have an option to have the run display To reset the electronic controller to its factory indicate different information. The information default for all settings (time, hardness, etc.): displayed on the top half of the display can be changed 1.
  • Page 22 Programming the Water Softener. POWER OUTAGE MEMORY ERROR SIGNALS If electrical power to the water softener is lost, If there is an error code “memory’’ built into the timer circuitry will keep detected, the blue Call for Service all settings for up to 24 hours. While the power indicator light will flash 4 is out, the display is blank and the water softener times every second, the...
  • Page 23: Care And Cleaning

    Care and cleaning. ADJUSTING YOUR WATER HARDNESS SERVICE POSITION (Normal Softener Operation) The blend adjusting knob (Figure 16) gives the ability to finely adjust hardness of the treated water Soft Water leaving the water softener. If slightly harder water Hard Pull is desired than is normally delivered by the water Water In...
  • Page 24: Care And Cleaning

    Always add if less than 1/4 full. Be sure the is needed. brinewell cover is on. GE recommends using Super Iron Out to clean ® NOTE: if using potassium chloride (KCI), do not fill your resin bed if your iron content is high.
  • Page 25: Routine Maintenance

    Routine Maintenance. CLEANING THE NOZZLE AND VENTURI ASSEMBLY A clean nozzle and venturi is needed for the water softening system to work properly. This small unit makes the suction to move brine from the salt storage area to the resin tank during recharge. If O-ring seal it becomes plugged with sand, dirt, etc., the water softening system will not work and you will get hard...
  • Page 26: Before You Call For Service

    NO SOFT WATER – Most Common Problems: Check the following before calling for service: from local water company, water test or call the GE Answer Center (800-952-5039 in US). the Breaking a Salt Bridge section. Problem...
  • Page 27 Before you call for service. Problem Possible Cause What to do Water hard some- Using hot water while the water times softening system is regenerating system recharge because the water heater will Bypass During Recharge section. Control HARDNESS number setting too low HARDNESS.
  • Page 28 Before you call for service. Problem Possible Cause What to do Excessive/high level Valve drain hose pinched, plugged, of water in brine elevated too high or otherwise operation of the nozzle and venturi and reduce or tank restricted prevent brine draw during recharge. Nozzle and venturi dirty, incorrectly assembled or damaged.
  • Page 29 Before you call for service. Problem Possible Cause What to do Error Codes on Wiring may have worked loose in Control the control to electronic board or switch. Reconnect as required. If “Err” in display Electrical problem with system...
  • Page 30 Advanced troubleshooting for service. AUTOMATIC ELECTRONIC DIAGNOSTICS 3. Symbols in the display indicate POSITION switch operation, (see Figure 19). This water softener has a self-diagnostic function Switch is open Switch is closed for the electrical system Call for Service (except into power and/ or water meter).
  • Page 31 Advanced troubleshooting for service. Service: Manually Advance Recharge Check NOTE: The control display must show a steady softening system into fast rinse. Again look for time (not flashing). a fast drain flow. Allow the water softening system to rinse for a few minutes to flush out 1.
  • Page 32: Exploded View/Parts List

    Exploded View.
  • Page 33 Exploded View. Wear Strip Seal Cross-section View...
  • Page 34 Parts List. REF. NO. GE PART NO. PART DESCRIPTION (01) BACK COVER, ELECTRONICS 0009 RESIN, 1-CU. FT. ACTIVATED CARBON 0012 FACEPLATE WITH POWER CORD WITH LABELS 0019 0022 BRINEWELL 0023 0026 WASHER WAVE 0109...
  • Page 35 Parts List. REF. NO. GE PART NO. PART DESCRIPTION (01) 0114 GASKET, NOZZLE/VENT 0115 CONE SCREEN NUT FERRULE 0123 PLUG, DRAIN SEAL 0124 NOZZLE/VENTURI ASM. SEAL KIT 0132 PLATE, MOTOR VALVE HARNESS WIRE, SENSOR ASSY 0148 0151 BYPASS ASM. 0998...
  • Page 36: Warranty

    GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location for service. In Alaska, the warranty excludes the cost of shipping or service calls to your home.
  • Page 37: Warranty

    Any part of the Water Softening System which fails due to defect in From the date of the materials or workmanship. During this limited one-year warranty, GE will original purchase also provide, free of charge, all labor and related service to replace the defective part.
  • Page 38 For Iowa Use Only. FOR IOWA USE ONLY All sales in Iowa require the following signature before consummation of sale. These signatures must be retained by seller/renter for 2 years minimum. Buyer/Renter ____________________________________________________Date__________________ Seller ___________________________________________________________Date__________________ Seller’s Address ________________________________________________________________________ Seller’s Phone No. _______________________________________________________________________ Model GXSH40V or Model GXSH45V...
  • Page 39 Notes.
  • Page 40 Notes.
  • Page 41 Información sobre Seguridad ..42 Especificaciones y Dimensiones ..43 Acerca del Suavizante ....46 Antes de Comenzar .
  • Page 42: Precauciones De Seguridad

    INFORMACIÓN IMPORTANTE DE SEGURIDAD. LEA TODAS LAS INSTRUCCIONES ANTES DEL USO. PRECAUCIONES DE SEGURIDAD ¡ADVERTENCIA! Por su seguridad, se debe seguir la información en este manual con el fin de reducir el riesgo de una descarga eléctrica, daños a la propiedad o daños personales. ADVERTENCIA: PELIGRO: Descarte...
  • Page 43 Reclamos por Especificaciones y Funcionamiento. Este modelo cuenta con una calificación de eficiencia. El índice de eficiencia es válido sólo con la dosis de sal mínima indicada. El suavizante cuenta con la función de regeneración de demanda iniciada (demand initiated regeneration, D.I.R.), que cumple con las especificaciones de funcionamiento para minimizar la cantidad de salmuera regenerante y agua usada en esta operación.
  • Page 44 Reclamos por Especificaciones y Funcionamiento. Modelo GXMH31H Capacidad Evaluada* (Granos por Dosis de Sal) 11,000 @ 2.6 lbs 24,700 @ 7.8 lbs. 31,100 @ 13.4 lbs. 4,240 @ 2.6 lbs.. Agua usada durante la Regeneración (galones/ granos) 5.0 /1000 Agua Total Usada por Regeneración en Dosis de Sal Mínima 54.7 galones...
  • Page 45 Sobre el sistema de descalcificación de agua. El Ablandador de Agua Híbrido de GE fue diseñado con para la preparación de comida o para beber, en el dos tipos de medios diferentes, uno de alta calidad que baño y en la ducha, lo cual reducirá el efecto estético...
  • Page 46 Sobre el sistema de descalcificación de agua. FUNCIONAMIENTO NORMAL, PANTALLAS DE CONTROL El sistema se recargará de forma automática en el Durante el funcionamiento normal, la hora actual tiempo de recarga presente, según sea necesario. del día y AM o PM y DAYS TO EMPTY (DÍAS HASTA VACIARSE) aparecen en el área de la pantalla de control.
  • Page 47 GE Point-Of-Entry con un filtro para Este hierro es visible de forma inmediata al salir por un la reducción de cloro.
  • Page 48: Antes De Comenzar

    Antes de comenzar. ANTES DE COMENZAR El suavizante de agua requiere un flujo mínimo de agua de 3 galones por minuto en la entrada. La presión de entrada de agua máxima tolerable es de 125 psi. Si la presión del día supera los 80 psi, es posible que la presión nocturna supere el máximo.
  • Page 49: Requisitos De Instalación

    Requisitos de Instalación. REQUISITOS DE UBICACIÓN NO HAGA CORRER AGUA CALIENTE A TRAVÉS DEL SUAVIZANTE La temperatura del agua que pasa a Considere todo lo siguiente al seleccionar una ubicación través del suavizante deberá ser inferior a 120º F. de instalación del suavizante de agua. No coloque el suavizante de agua donde haya Evite la instalación directamente en contacto con la temperaturas heladas.
  • Page 50 Requisitos de Instalación. CÓDIGOS DE PLOMERÍA REQUISITOS DEL DRENAJE CON VÁLVULA Toda la plomería deberá ser completada de Para el uso de una manguera de drenaje flexible acuerdo con los códigos de plomería nacional, (incluida) (vea la Figura 2), mida y corte hasta la estatal y local.
  • Page 51 Requisitos de Instalación. REQUISITOS DE PLOMERÍA INTERIOR/ 3-SISTEMA DE DESVIACIÓN CON VÁLVULA EXTERIOR Para el servicio con agua suave: Abra las Siempre instale una válvula de desviación simple válvulas internas y externas y cierre la válvula de (provista), como se muestra en la Figura 4, o, si lo desviación.
  • Page 52: Instrucciones De Instalación

    Instrucciones de Instalación. INSTALACIÓN TÍPICA Abrazadera Tubería de Agua con Conexión Agua Dura Principal Agua a Tierra hacia Grifos Acondicionada Externos Tubería Agua Dura Abrazadera con Cubierta Entrante Conexión a Tierra Sujetadores Adaptador de Superior Transpiración Transfor- NPT de 1” (no Ensamble de mador de incluido)
  • Page 53 Instrucciones de Instalación. CIERRE EL SUMINISTRO DE AGUA 1. Cierre la válvula del suministro principal de agua, ubicada Ensamble cerca de la bomba del pozo o del medidor de agua. Tapa de de Boquilla 2. Abra todos los grifos para drenar toda el agua de las tuberías la Sal y Venturiy de la casa.
  • Page 54 Instrucciones de Instalación. COMPLETE LA PLOMERÍA DE ENTRADA Y SALIDA Complete la tubería interna y externa sobre el tipo de tubería que usará. Asegure la abrazadera con conexión a ¡ADVERTENCIA! tierra a las tuberías de metal. INSTALE LA MANGUERA DE DRENAJE DE LA RIESGO DE DESCARGA ELÉCTRICA: VÁLVULA Instale una clavija de metal con conexión a...
  • Page 55 Instrucciones de Instalación. ENJUAGUE EL POLVO FINO DEL CARBÓN (b). Desvío de la Válvula: Cierre totalmente la válvula de desviación y abra la válvula de salida. Lentamente Pequeñas partículas del material de filtrado del carbón abra la válvula de entrada, haciendo varias pausas son generadas durante la fabricación y el embalaje.
  • Page 56 Instrucciones de Instalación. AGREGUE AGUA Y SAL AL TANQUE DE DESINFECTE EL SUAVIZANTE DE AGUA/ ALMACENAMIENTO DE SAL DESINFECTE LUEGO DEL SERVICIO 1. Abra la tapa del agujero de sal, retire la tapa del ¡ADVERTENCIA! pozo de salmuera y vierta alrededor de 3 oz. (6 RIESGO DE PESO EXCESIVO: cucharones) de blanqueador de hogar en el pozo Cuente con la ayuda de dos o más...
  • Page 57: Programación Del Suavizante

    Programación del Suavizante de Agua. Cuando el transformador está enchufado en el CONFIGURE LA HORA DEL DÍA tomacorriente eléctrico, un código de modelo 1. Presione el botón MODE/SET (Modo/ y número de evaluación (ejemplo: J3.4 & H45) Configuración) hasta que la flecha apunte a aparecen en la pantalla.
  • Page 58 Programación del Suavizante de Agua. CONFIGURE EL NÚMERO DE DUREZA DEL CONFIGURACIÓN DEL TIEMPO (INICIAL) DE AGUA RECARGA 1. Presione el botón MODE/SET (Modo/ 1. Presione el botón MODE/SET (Modo/ Configuración) hasta que la flecha apunte a Configuración) hasta que la flecha apunte a HARDNESS (Dureza).
  • Page 59 Programación del Suavizante de Agua. CONFIGURE EL NIVEL DE SAL DÍAS HASTA VACIARSE 1. Presione el botón MODE/SET (Modo/ Configuración) Las palabras DAYS TO EMPTY (DÍAS HASTA VACIARSE) hasta que la flecha apunte a SALT LEVEL (Nivel y un número se muestran en la mitad inferior de Sal).
  • Page 60 Programación del Suavizante de Agua. CONFIGURACIONES OPCIONALES DEL CONTROL LAVADO REGRESIVO Y ENJUAGUE RÁPIDO La pantalla del controlador cuenta con varias opciones y Si siente que el sabor del agua es salado luego de la funciones. regeneración, es posible que necesite incrementar los tiempos del lavado regresivo y de enjuague rápido.
  • Page 61 Programación del Suavizante de Agua. FUNCIÓN: PANTALLA DE OTROS DATOS REAJUSTE A FALTA DE FÁBRICA Estos modelos tienen una opción para que la pantalla indique Para reiniciar el controlador electrónico de todas las información diferente. La información mostrada en la mitad configuraciones al ajuste de fábrica por omisión (hora, superior de la pantalla puede ser modificada a una de las dureza, etc.)
  • Page 62 Programación del Suavizante de Agua. MEMORIA POR CORTE DE CORRIENTE SEÑAL DE NIVEL DE SAL BAJO Si se corta la corriente del suavizante de agua, Cuando la función DAYS TO EMPTY (Días Hasta la “memoria” incorporada en los circuitos Vaciarse) cae a 15, la luz azul indicadora y DAYS del temporizador mantendrán todas las TO EMPTY (Días Hasta vaciarse) en la pantalla configuraciones durante hasta 24 horas.
  • Page 63: Cuidado Y Limpieza

    Cuidado y limpieza. AJUSTE DE LA DUREZA DEL AGUA POSICIÓN DEL SERVICIO La perilla de ajuste de mezcla (Figura 16) le da la posibilidad (Funcionamiento Normal del Suavizante) de ajustar finamente la dureza del agua tratada, dejando Agua Suave el suavizante de agua. Si se desea un agua un poco más Agua Dura Afuera Manija de Empuje...
  • Page 64 Siempre agregue sal cuando la cantidad sea inferior a ¼. Asegúrese de que la tapa del pozo de GE recomienda el uso de Super Iron Out® para salmuera esté colocada. limpiar el lecho de resina si el contenido de hierro es alto.
  • Page 65: Rutina De Mantenimiento

    Rutina de Mantenimiento. LIMPIEZA DEL ENSAMBLE DE LA BOQUILLA Y EL VENTURI Tapa Una limpieza de la boquilla y el venturi es necesaria para que el sistema suavizante funcione de forma correcta. Esta pequeña unidad hace que la succión mueva la salmuera del área de almacenamiento de sal al tanque de Sello del anillo o resina durante la recarga.
  • Page 66: Antes De Solicitar El Servicio

    Configuración de dureza demasiado baja. Controle la configuración de la dureza y haga un ajuste. Verifique la dureza del agua suministrada - de la empresa de agua local, evaluación del agua o llame a GE Answer Center (800-952-5039 en EE.UU.).
  • Page 67 Antes de solicitar el servicio técnico. Problema Causa Posible Qué hacer Agua dura a veces Uso de agua caliente mientras el sistema suavizante de agua se está sistema suavizante de agua, ya que el calentador regenerando de agua se volverá a llenar con agua dura. Consulte la sección de Desviación del Agua Dura Durante la Recarga de DUREZA demasiado bajo...
  • Page 68 Antes de solicitar el servicio técnico. Problema Causa Posible Qué hacer Nivel excesivo/alto de La válvula de la manguera de drenaje agua en el tanque de está pinzada, atascada, demasiado podrá impedir un funcionamiento correcto de la salmuera elevada o de algún modo restringida boquilla y el venturi y reducir o impedir el ingreso de salmuera durante la recarga.
  • Page 69: Técnico

    Antes de solicitar el servicio técnico. Problema Causa Posible Qué hacer Códigos de Error en el Es posible que el cableado se haya Control costado. incorrectas al tablero electrónico o interruptor. Vuelva a conectar según se requiera. Code (Código de Error). técnico.
  • Page 70 Solución de problemas avanzados para el servicio técnico. DIAGNÓSTICO ELECTRÓNICO AUTOMÁTICO Los símbolos en la pantalla indican el funcionamiento del interruptor de POSICIÓN. Vea la Figura 19 Este suavizante de agua cuenta con una función de auto Switch is open Switch is closed diagnóstico del sistema eléctrico (excepto para la corriente...
  • Page 71 Solución de problemas avanzados para el servicio técnico. Servicio: Control de Recarga Avanzado en forma Manual NOTA: La pantalla de control debe mostrar el horario de 4. Presione el botón RECHARGE (Recarga) para pasar manera fija (no titilando). el sistema suavizante de agua al enjuague rápido. Nuevamente bosque un flujo de drenaje rápido.
  • Page 72 Vista Expandida.
  • Page 73 Vista Expandida. Wear Strip Seal Cross-section View...
  • Page 74: Vista Ampliada/ Listado De Piezas

    Listado de Piezas. REF. NO. GE PART NO. PART DESCRIPTION (01) CARBÓN ACTIVADO 0012 PLACA 0013 CONTROL SIN CABLE DE CORRIENTE CON ETIQUETAS 0019 BORDE 0023 KIT DE TORNILLOS. TANQUE DE SALMUERA 0026 KIT DEL ADAPTADOR PARA DESBORDES 0056 KIT DE LA CLAVIJA DEL CUELLO DEL TANQUE...
  • Page 75 Listado de Piezas. REF. NO. GE PART NO. PART DESCRIPTION (00) (00) 0132 KIT DEL ADAPTADOR DE LA MANGA DE DRENAJE CABLE DEL HARNÉS, ENSAMBLE DE SENSOR, 1” 0148 TURBINA Y SOPORTE ASM.* 0999 49-50295 MANUAL DEL PROPIETARIO * INCLUYE 2 del Nº de REF. 145 (GANCHO) y Nº de REF. 152 (ANILLO EN O)
  • Page 76: Garantía (Ee.uu.)

    Ubicación del Servicio Técnico de GE Autorizado para recibir el servicio. En Alaska, la garantía excluye el costo de envío o llamadas del servicio a su hogar.
  • Page 77 Un Año Cualquier pieza del Sistema Suavizante de Agua que falle debido a un defecto en los materiales o la fabricación. Durante esta garantía limitada de un año, GE tam- Desde la fecha de bién proveerá, sin costo, todo el trabajo y el servicio relacionado con el reemplazo compra original.
  • Page 78 Nota. SÓLO PARA USO EN IOWA deberán ser conservadas por el vendedor/ arrendatario por un mínimo de 2 años Comprador/ Arrendatario __________________________________________Fecha ________________ Vendedor _______________________________________________________Fecha ________________ Domicilio del Vendedor __________________________________________________________________ Nº Telefónico del Vendedor ______________________________________________________________ Model GXSH40V or Model GXSH45V...
  • Page 79 Nota.
  • Page 80 Manuales de los Propietarios o pedir piezas en línea. Solicite una reparación GEAppliances.com El servicio de expertos GE está a tan sólo un paso de su puerta. Llame al 800.GE.CARES (800.432.2737) durante horas normales de oficina para solicitar su reparación. Real Life Design Studio (Estudio de diseño para la vida real)
  • Page 81 Contact Us GEAppliances.com If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations...

This manual is also suitable for:

Gxsh45vGxsh40v

Table of Contents