Service: Manually Initiated Electronic Diagnostics
On
LAST RECHARGE
WATER MANAGEMENT SYSTEM
Turbine
Switch
Turbine
count
Valve
Minutes of cycle
position
remaining
Fill
TIME
WATER MANAGEMENT SYSTEM
Turbine
To enter diagnostics, press and hold the DATA
1
button until the display appears as shown.
NOTE: If the water softening system is in the middle of a
regeneration, top part of the display shows the cycle of
regeneration and minutes of the cycle remaining. If two
cycle names are flashing, the valve is in transition
between the cycles.
A The three digits under WATER MANAGEMENT
SYSTEM indicate water meter operation as follows:
000 (steady) = soft water not in use...no flow
through the meter.
—OPEN A NEARBY SOFT WATER FAUCET—
000 to 199 (continual) = repeats display for
each gallon of water passing through the
meter.
Position
switch
Valve
outlet
If you don't get a reading in the display, with
faucet open, pull the sensor from the valve outlet
port. Pass a small magnet back and forth in front
of the sensor. You should get a reading in the
display. If you get a reading, unhook the in and
out plumbing and check the turbine for binding.
Motor
Sensor
housing
Turbine
Turbine
support &
shaft