Identifying Disk Drive Problems

For recovery operations, refer to

Table 10-2. Possible Causes of Common Disk Drive Problems

Problems
Disk is full or does not have enough space.
Disk free space is fragmented.
One disk in a mirrored pair is down.
An unmirrored disk is down, or both disks
in a mirrored pair are down.
Performance problems occur due to path
switches or a cache size that is too small.
Defective tracks or sectors exist.
Disk errors exceed a certain limit.
Slow I/O operations exceed a certain limit.

Internal SCSI Disk Drives

The most common disk drive problems on a NonStop S-series server include:
Space problems such as full disks or free-space fragmentation
Stopped disks
Performance problems
Defective tracks or sectors

M8xxx Fibre Channel Disk Drives

The most common disk problems on an Integrity NonStop NS-series server are intm-
errors-exceeded and slow-IOs-threshold-exceeded errors on the Fibre Channel loop.
Such errors are often normal. However, if they cause problems on a Fibre Channel
loop, power the affected disk down and up again. This procedure can solve the
problem temporarily.
Unless you are a qualified service provider, you cannot perform any physical actions
on disk drives. However, operators can use OSM and SCF commands.
HP Integrity NonStop NS-Series Operations Guide —529869-005
Recovery Operations for Disk Drives
Possible Symptoms
Error 43 (unable to obtain disk space for file
extent) occurs.
If the disk is full, an application might go down.
The storage subsystem generates an event
message but the application continues to run.
Users report access problems, applications go
down, and the storage subsystem generates
event messages.
Users report poor application performance.
Output from SCF INFO DISK, BAD command
indicates unspared defective sectors.
Intm-errors-exceeded message