Environmental And Physical - Comtech EF Data CDD-880 Installation And Operation Manual

Multi receiver router
Hide thumbs Also See for CDD-880:
Table of Contents

Advertisement

CDD-880 Multi Receiver Router
Introduction
1.4.3

Environmental and Physical

Parameters
Operating
Temperature
Storage
Operating
Humidity
Storage
AC
Power Supply
DC
AC
Operating
Voltage
DC
Power Consumption
Fuse
Physical Dimensions
Weight
Agency Approvals
Specifications
32 to 122°F (0 to 50°C)
-4 to 158°F (-20 to 70°C)
95% maximum, non-condensing
99% maximum, non-condensing
Includes an on/off switch
Includes an on/off switch and an input filter per PL-0000551 and PL/10312-1 Kits
100 – 240 Volts AC +6%/-10% autosensing (total absolute max. range is 90 – 254 volts AC)
48 Volts nominal (total range is 36 to 60 volts)
60 W typical
120/230 VAC: T3.15A, slow-blow 20 mm
48VDC (38 to 60 VDC): T8.0A, slow-blow 20 mm
1RU high x 19 inches wide x 16 inches deep
( 43.8 mm h x 482.6 mm w x 406 mm d)
7 lbs (3.2 kg)
CE Mark
FCC Part 15, Class B
1–10
Revision 0
MN-CDD880

Advertisement