VIEW_LOGS_PRIV is a Boolean parameter that gives the user permission to
view the iLO system logs. This parameter is optional, and the Boolean string
must be set to "Yes" if the user should be allowed to view logs. If this parameter
is used, the Boolean string value must never be blank.
CLEAR_LOGS_PRIV is a Boolean parameter that gives the user permission to
clear the event log. This parameter is optional, and the Boolean string must be set
to "Yes" if the user should be allowed to clear the iLO event log. If this
parameter is used, the Boolean string value must never be blank.
EMS_PRIV is a Boolean parameter that gives the user permission to use the
Windows® Server 2003 EMS service. This parameter is optional, and the
Boolean string must be set to "Yes" if the user should be allowed to use EMS
services. If this parameter is used, the Boolean string value must never be blank.
UPDATE_ILO_PRIV is a Boolean parameter that allows the user to copy a new
firmware image into the iLO system ROM. This parameter is optional, and the
Boolean string must be set to "Yes" if the user should be allowed to configure
iLO. If this parameter is used, the Boolean string value must never be blank.
CONFIG_RACK_PRIV is a Boolean parameter that gives the user permission to
configure and manage the server rack resources. This parameter is applicable to
ProLiant BL p-Class servers only. This parameter is optional, and the Boolean
string must be set to "Yes" if the user should be allowed to manage or configure
rack resources. If this parameter is used, the Boolean string value must never be
blank.
DIAG_PRIV is a Boolean parameter that gives the user permission to view
diagnostic information about iLO. This parameter is optional, and the Boolean
string must be set to "Yes" if the user should have diagnostic privileges. If this
parameter is used, the Boolean string value must never be blank.

ADD_USER Runtime Errors

The possible ADD_USER error messages include:
Login name is too long.
Password is too short.
Password is too long.