SEC_WINS_SERVER specifies the IP address of the secondary WINS server.
This parameter is only relevant if the DHCP-assigned WINS server address
feature is disabled. If an empty string is entered, the current value is deleted.
STATIC_ROUTE_1, STATIC_ROUTE_2, and STATIC_ROUTE_3 are used to
specify the destination and gateway IP addresses of the static routes. The
following two parameters are used within the static route commands. If an empty
string is entered, the current value is deleted.
WEB_AGENT_IP_ADDRESS specifies the address for the Web-enabled agents.
If an empty string is entered, the current value is deleted.

MOD_NETWORK_SETTINGS Runtime Errors

The possible MOD_NETWORK_SETTINGS error messages include:

GET_GLOBAL_SETTINGS

The GET_GLOBAL_SETTINGS command requests the respective iLO global
settings. For this command to parse correctly, the command must appear within a
RIB_INFO command block, and RIB_INFO MODE can be set to read or write.

GET_GLOBAL_SETTINGS Parameters

None
DEST specifies the destination IP addresses of the static route. This
parameter is only relevant if the DHCP-assigned static route feature is
disabled. If an empty string is entered, the current value is deleted.
GATEWAY specifies the gateway IP addresses of the static route. This
parameter is only relevant if the DHCP-assigned static route feature is
disabled. If an empty string is entered, the current value is deleted.
RIB information is open for read-only access. Write access is required for
this operation.
User does not have correct privilege for action. CONFIG_ILO_PRIV