Inability To Connect To The Ilo Processor Through The Nic - HP Integrated Lights-Out User Manual

Hp integrated lights-out user guide
Hide thumbs Also See for HP Integrated Lights-Out:
Table of Contents

Advertisement

1. Have only one active NIC on the client workstation. For example, disable the
2. Configure the IP address of the client workstation network to match the iLO

Inability to Connect to the iLO Processor through the NIC

If you cannot connect to the iLO processor through the NIC, try any or all of the
following troubleshooting methods:
Firmware upgrade
Remote Console session
SSL initialization
If you are using a client workstation that contains more than one enabled
NIC, such as a wireless card and a network card, a routing issue might
prevent you from accessing the diagnostic port. To resolve this issue:
wireless network card.
Diagnostic Port network.
a. The IP address setting should be 192.168.1.X, where X is any number
other than 1, because the IP address of the diagnostic port is set at
192.168.1.1.
b. The subnet mask setting should be 255.255.255.0.
Confirm that the green LED indicator (link status) on the iLO RJ-45
connector is on. This indicates a good connection between the PCI NIC and
the network hub.
Look for intermittent flashes of the green LED indicator, which indicates
normal network traffic.
Run the iLO RBSU to confirm that the NIC is enabled and verify the
assigned IP address and subnet mask.
Run the iLO RBSU and use the F1-Advanced tab inside of the DNS/DHCP
page to see the status of DHCP requests.
Ping the IP address of the NIC from a separate network workstation.
Attempt to connect with browser software by typing the IP address of the
NIC as the URL. You can see the iLO Home page from this address.
Reset iLO.
Troubleshooting iLO
375