Maintenance; Troubleshooting - Axminster BDS-612 User Manual

Belt & disc sander trade series
Table of Contents

Advertisement

Maintenance

DISCONNECT THE SANDER FROM
THE MAINS SUPPLY BEFORE
CONTINUING!
There is very little mechanical maintenance that can be
carried out on the machine. Most prudent maintenance
is preventative and concerned with keeping the machine
clean.
1. At reasonable intervals, inspect and remove all dust/resin
build ups, and blow the motor clean.

Troubleshooting

Trouble
Motor does not run when power
switch is pressed "ON"
Motor does not run at full speed
Motor does not reach full power
Motor overheating
Motor stalls while in use
2. Remove the table assembly and lower the extraction
housing, clean any dust or resin build up. Re-assemble the
sander.
3. Inspect the sanding disc for signs of wear and tear and
replace if necessarily.
4. Inspect the linisher's sanding belt for signs of wear and
tear and replace if necessary.
5. From time to time using a damp cloth wipe over the
sander's surface.
Probable Cause
1. Switch is burnt out
2. Connection wire is loose or
damaged
1. Power voltage is too low
2. Motor is damaged.
1. Incorrect power wiring
2. Overloaded
1. Motor voltage is different
2. Motor is damaged
1. To much pressure being placed on
sanding surface.
2. Motor getting too hot.
20
Remedy
1. Replace the switch
2. Tighten wire or replace
1. Test voltage
2. Check and repair motor
1. Replace with the correct size of
power wiring
2. Reduce load
1. Check the voltage label
2. Check and repair the motor
1. Don't press to heavily on abrasive
surface.
2. Leave the sander to cool down for 30
minutes and press the "RESET" button

Advertisement

Table of Contents
loading

Table of Contents