Setup - MULTIQUIP LT6D Operation Manual

Light tower/generator (kohler kdw 1003 diesel engine)
Table of Contents

Advertisement

InDOOR InsTaLLaTIOn
Exhaust gases from diesel engines are extremely
poisonous. Whenever an engine is installed indoors the
exhaust fumes must be vented to the outside. The engine
should be installed at least two feet from any outside wall.
Using an exhaust pipe which is too long or too small can
cause excessive back pressure which will cause the engine
to heat excessively and possibly burn the valves.
Eliminate the danger of deadly carbon monoxide gas.
Remember that exhaust fumes from any gasoline or diesel
engine are very poisonous if discharged in a closed area.
If the light tower is installed indoors, you must make
provisions for venting the engine exhaust to the outside
of the building.
Lamp pOWeR CaBLe COnneCTIOns
1. Locate the 4 key-lock female 3-pin DIN connectors on
the T-bar as shown in Figure 12.
A
Figure 12. 3-Pin DIN Female Connector
2. Next, locate the slot or key (A) on each female
connector as shown in Figure 12.
3. On the corresponding male connector, locate the key
tab (B) as shown in Figure 13.
B
Figure 13. Male Connector
page 30 — LT6D LIgHT TOWeR • OpeRaTIOn manuaL — Rev. #0 (07/16/13)
4. Align the key tab (B) on the male connector with the slot
or key (A) on the female connector and press together
until seated. Connect the light power cables to the T-bar
as referenced in Table 7 and Figure 14.
Table 7. Light power Cable Connections
power Cable
Light 1
Light 2
Light 3
Light 4
T 1
L I G H
J1
2
H T
L I G
Figure 14. Light Power Cable Connections
5. Secure all cable connectors by screwing the knurled
locking nut of the male connector to the threaded
portion of the female connector to ensure good contact
between the two connectors. See Figure 14.

setup

T-Bar Receptacle
J1
J2
J3
J4
J3
J4
J2
MAST RAISED