Installation - Windster RA34LU30SS User Manual

Under cabinet series,wall mount series
Hide thumbs Also See for RA34LU30SS:
Table of Contents

Advertisement

j.
Use a spirit level to ensure the balance of the hood is true.
k.
Mount the unit onto wall with mounting screws (not included) (Fig. 2b)
l.
Determine the desired location for mounting the duct cover bracket and
secure it with the (2) screws provided. (Fig. 2c)
NOTE: IF USING CFM reducer, connect the reducer to unit
before continuing.
m. Connect 6" ducting to the collar of the unit and secure it with aluminum
tape. (Fig. 2d)
n.
Adjust the duct cover to the desired height and slide it into the duct cover
mounting panel and bracket. (Fig. 2e)
o.
Secure it with the (2) duct cover screws provided. (Fig. 2f)
3. COLD WEATHER INSTALLATION (OPTIONAL)
a.
Check with your local building codes to see if a CFM reducer is an
acceptable alternative to make-up air.
b.
Remove the RA34LCFMR (CFM Reducer) and inspect for any sign of
defect or damage. (ie. Cracks, broken flips)
For UNDER CABINET installation: COMPLETE Step A – D of Section
c.
1 UNDER CABINET INSTALLATION THEN GO TO STEP E BELOW.
For WALL MOUNT installation: COMPETE Step A – J of Section 2
d.
WALL MOUNT INSTALLATION THEN GO TO STEP E BELOW.
e.
Place the CFM reducer onto the outlet of the unit and seal the connection
point with aluminum tape. (Be sure it is secure with no opening or gaps)
Connect a 6" ducting to the collar of the CFM reducer.
f.
g.
Finish off by sealing the connection point with aluminum tape.

INSTALLATION

9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ra34lu36ssRa34lu42ssRa34lu48ss

Table of Contents