Switch off
(never / after 30 min. / 60 min. / 90 min. / 120 min. /
150 min. / 180 min.)
Default value: never
The time after the last beverage is dispensed is
adjusted here. If this time is exceeded, the coffee
machine automatically shuts off.
It can be set in increments of 30 minutes.
temperature
Boiler
The boiler water temperature is set here. (coffee
brewing water temperature)
Water filter
Options:
• active
Default value:
active Water filter is fitted. Capacity and water
hardness are queried.
Filter capacity (water filter)
If the water filter is active, the filter capacity in liters is
entered here.
Measured carbonate hardness
Enter the measured water hardness in °dKH here.
Measured total water hardness
Machine options
For Service only.
User Manual WMF 1500 S
• inactive
inactive
Software | System
Temperature
Water filter
instructions
If the water hardness is between
0 and 4 °dKH, no water filter is
needed.
Water filter capacity
w p age 41
Machine options
49