Installation clearances For operating, service, and safety reasons the
Installation dimensions
of the water filter
these specifications for the electrical connection and the standards quoted
apply for connecting the coffee machine in EU countries. it may be necessary
to also observe additional country-specific regulations. outside the EU
countries acceptance of the standards quoted is to be checked by the legal
entity or natural person who wishes to use the coffee machine.
The local power supply must be constructed according to IEC 364 (DIN VDE 0100).
To improve safety, the device should be fitted with an FI 30 mA earth leakage
current circuit breaker complying with EN 61008. (Type B residual current circuit
breakers provide reliable tripping even if the fault current is smooth. This ensures
a high level of safety.) Near the device or about 30 cm below the counter top there
should be a shockproof socket as a single-phase connection installed locally on
the rear or side wall of the counter substructure or a country-specific single-phase
socket. The mains switch and plug top are part of the on-site installation. The
mains cable must not come into contact with hot surfaces. If the mains cable
for this device is damaged then it must be replaced by our service personnel
or a similarly qualified person, in order to prevent hazards. The coffee machine
may not be fitted with a fixed permanent mains connection if installed on
a transporting trolley (a mobile station).
In order to avoid possible faults from arising on our shielded data lines due to
potential equalisation currents between the devices, an additional potential
equalisation unit should be planned for devices connected to the vending system.
(See EN 60309)
User Manual WMF 1500 S
machine should be installed with a clearance of not
less than 50 mm at the sides from the building or
non-WMF components.
A minimum working space of 800 mm in front of the
coffee machine is recommended. A clear height of
1,100 mm from the top of the supporting surface should
be ensured. The height of the installation surface above
the floor is at least 850 mm. If the coffee machine
connections are to be run downwards through the
counter, please make space for the lines, which can
reduce the usable space below the machine.
See the User Manual for the water filter.
Appendix: Technical data