Description Of Machine I/O Monitoring Display - Acer Supra 818PD Operation Manual

High precision automatic surface grinder
Hide thumbs Also See for Supra 818PD:
Table of Contents

Advertisement

4-4
DESCRIPTION OF MACHINE I/O MONITORING DISPLAY (Enter from
① ②
NO.
DESCRIPTION
1
Lamp numbers
Output signal
2
point
Function
3
description
① ②
NO.
DESCRIPTION
1
Lamp numbers
Input signal
2
point
Function
3
description
These are I/O monitoring lamp numbers. When external function,
device and coil are conducted, the red lamp lights on. If not
conducted, the red lamp extinguishes.
These are output signal points (Y00~YO7, Y10~Y17, Y20~Y27,
Y30~Y37 and Y40~Y47). All together 5 pages.
Each output signal corresponds to its function (device or coil)
These are machine I/O monitoring lamp numbers. When external
function, switch and push-button signals are conducted, the green
lamp lights on. If not conducted, the red lamp lights on.
These are input signal points (X00~X07, X10~X17, X20-1~X27-1,
X20-2~X27-2, X20-3~X27-3, X20-4~X27-4 and X20-5~X27-5).
Total 7 pages.
Each input signal corresponds to its function (switch or
push-button)
FUNCTION DESCRIPTION
FUNCTION DESCRIPTION
27