5-4-1 ALARM MESSAGE
ALARM
NO.
001
Y-axis stepping motor is overheat
Z-axis servo motor driver is abnormal.
002
Check it.
Grinding wheel motor, hydraulic motor
003
or Y-axis elevation motor or coolant
motor is overload and skipped.
004
Lubrication oil level is insufficient
005
Lubrication motion fails
Y-axis top limit switch is touched. Move
006
Y-axis down.
Z-axis forward limit switch is touched.
007
Move Z-axis backward.
Z-axis backward limit switch is
008
touched. Move Z-axis forward.
Z-axis forward direction change
009
proximity sensor is abnormal. Check it.
Z-axis backward direction change
010
proximity sensor is abnormal. Check it.
X-axis move leftward direction change
011
proximity sensor is abnormal. Check it.
X-axis move rightward direction
012
change proximity sensor is abnormal.
Check it.
Y-axis stepping motor positioning
013
incorrectly.
Z-axis stepping motor positioning
014
incorrectly.
Battery voltage for PLC control is too
015
low. Replace it.
ALARM
MESSAGE
CORRECTION
Check if there is any obstacle existing on Y-axis
travel, which may cause Y-axis motor overload
and overheat. After check, reset it.
Check the error code displayed on the Z-axis
servo motor driver. Refer to alarm code given in
the operation manual for correction. After
check, reset it.
Check if grinding wheel motor, hydraulic motor,
Y-axis elevation motor or coolant motor runs
abnormally that may cause motor overload and
skip. Reset the overload protector. After check,
reset it.
Check if lubrication oil level is too low or oil
leaked or not. After check, reset it.
Check if lubrication oil hose or oil shooting is
normal or not. After check reset it.
Check if Y-axis top limit switch is touched or not.
If touched, manually move Y-axis down to leave
from the limit switch. Or check if the limit switch
works normally or not. After check, reset it.
Check if Z-axis forward limit switch is touched or
not. If touched, manually move Z-axis backward
to leave from the limit switch. Or check if the
limit switch work normally or not. After check,
reset it.
Check if Z-axis backward limit switch is touched
or not. If touched, manually move Z-axis
forward to leave from the limit switch. Or check
if the limit switch works normally or not. After
check, reset it.
Check if Z-axis forward direction change
proximity sensor is damaged or not. After
check, reset it.
Check if Z-axis backward direction change
proximity sensor is damaged or not. After
check, reset it.
Check if X-axis move leftward direction change
proximity sensor is damaged or not. After
check, reset it.
Check if X-axis move rightward direction
change proximity sensor is damaged or not.
After check, reset it.
Check Y-axis motor driver.
1. To screen→ Set Y-axis
Check Z-axis motor driver
increasing acceleration
1. To screen→ Set Z-axis parameter for
2. Turn on the Y-axis stepping motor driv
increasing acceleration / deceleration time.
again.
2. Turn on the Z-axis stepping motor driver
again.
When the message displays, contact the
machine manufacturer for purchasing battery
40
818~2040PD
parameter for
/ deceleration time.
er