___________________________________________________________________________
4.5 ELECTRIC WIRING:
a. It's a power wire for coolant with dust collector unit, which should be connected to a socket
marked with
b. The power wire of hydraulic system should be connected to a socket marked
with
c. It's a power wire for magnetic chuck.
d. These are main power wires of the machine, which should be connected to correct voltage
of power source. It is requested to check if the power wires are connected to the correct
terminals.
e. After power wires have been connected, turn power switch on for checking if motor runs
clockwise or not. If not, you need to change any two of the three-phase power wires (L1, L2,
L3).
, located at the back side of the electrical cabinet.
, located at the back side of the electrical cabinet.
4-6
818~2040 PD