Mode Select - HP Q153090901 Technical Reference Manual

Ultrium tape drives generation 3 drives volume 3-the scsi interface
Table of Contents

Advertisement

MODE SELECT

M
is used to send configuration data to the drive. Both 6-byte and 10-byte versions of
ODE SELECT
the command are supported.
The Mode Select parameter list is transferred from the host to the drive during the data-out phase.
It contains zero or more bytes of information. If any information is sent, it should consist of a Mode
Parameter Header followed by zero or more mode select pages. Internal parameters are set
according to the values specified in the header and pages. Fields in the parameter list are checked
and the operation will terminate if an error is found.
The drive does not check that the parameter list is correct before modifying internal
NOTE:
parameters. The list is checked as the operation proceeds, so if there is an error in the list, all
parameters up to that point will be set to their new values, but the parameter in error and later
parameters will not be updated.
Pre-execution checks:
Illegal Field
NOTE:
Failure to flush write-behind data will be reported as a Deferred Error.
The parameter list length must be such that only "entire" parts of a parameter list are sent. It is
illegal to send a partial mode parameter header, a partial mode block descriptor or a partial
mode page. If this happens, then
ILLEGAL REQUEST
Extra checks may be performed on the data, see the descriptions for the parameter list for more
details.
Command descriptor block
6-Byte version
7
0
1
2
3
4
5
Reservation
Deferred Error
CHECK CONDITION
. The additional sense is set to 1A00h (parameter list length error).
6
5
Operation Code (15h)
Reserved (0)
Parameter List Length
Unit Attention
status is reported. The sense key is set to
4
3
2
PF
Reserved (0)
Reserved (0)
Reserved (0)
Control
15h/55h
1
0
SP (0)
MODE SELECT 15h/55h