Cisco uBR-3x10 Hardware Installation And Cabling Manual page 115

Rf switch
Table of Contents

Advertisement

Chapter 6
Troubleshooting
Troubleshooting the Ethernet Controller
RFswitch App
The RfswitchApp (residing in flash memory) is the main system firmware component. It provides full
network functionality (Telnet, TFTP, SNMP Agent) and line card control. The SysLoader (residing in
boot flash memory) is a special build of the RfswitchApp firmware without SNMP agent support or line
card control functionality to help increase reliability, because it is normally invoked as a result of a
system crash. The SysLoader is capable of sending SNMPv1 traps as simple UDP packets, and fully
supports Telnet and TFTP operations.
The Ethernet controller firmware is structured into three parts, the ROMMON, the SysLoader, and the
main RfswitchApp. The SysLoader component is stored in onboard flash memory designated as the
bootflash memory. The RfswitchApp resides in a separate area designated as flash memory.
The ROMMON is the first component to run. It is invoked whenever a reset event occurs, either by
bootup, system crash, or software reload. The ROMMON is responsible for determining the cause of the
reset event and controls the next phase of system bootup.
If the reset event is because of a system crash, the ROMMON attempts to load the SysLoader from
bootflash memory into RAM and run it. If the bootflash memory is invalid, the ROMMON will then
attempt to load the RfswitchApp from flash as a last resort. If the cause of the reset event was a normal
bootup or reload, then an attempt is made to load and run the RfswitchApp. If this fails, then an attempt
is made to load and run the SysLoader.
The system prompt changes from rfswitch> to Sys> if the SysLoader is running. If the ROMMON is
Note
unable to load either the SysLoader or RfswitchApp, then it remains in control, and the controller's SYS
LED is off and the ERR LED flashes.
Ethernet Controller LEDs
If the Ethernet controller LEDs do not come on as expected, check the following items:
OL-1984-06
SYS LED is on, ERR LED is off
System has successfully booted
All LEDs remain off
Troubleshoot the power subsystem
SYS LED is off, ERR LED is on
The system has detected a bootup error or system crash event. Use the show log command to
view the system event log to determine the cause of the problem.
SYS LED is on, ERR LED is on
A problem has been detected configuring or controlling the switch modules. One or more of the
switch modules ERROR LEDs is on. If so, refer to the
Downstream Switch Modules" section on page
6-6.
Cisco uBR-3x10 RF Switch Hardware Installation and Cabling Guide
Troubleshooting the Installation and Setup
"Troubleshooting Upstream and
6-3