Replacement Parts; Convection Blower Replacement; Exhaust Blower Replacement - Pelpro PP60 Owner's Manual

Pelpro pp60 pellet stove owner's manual
Hide thumbs Also See for PP60:
Table of Contents

Advertisement

5

Replacement Parts

A. Convection Blower Replacement
1. Turn the dial control to the off position. Unplug the power
to the unit.
2. The convection blower is located in the rear of the unit.
3. Using #2 Phillips screwdriver, loosen the bolts on the
rear of the unit holding on the side panels. You do not
need to remove the screws. Remove side panels by
lifting up and out.
4. Unplug the wires from the convection blower motor from
the right side of the unit.
5. Remove the two screws holding the convection blower
housing to the sheet metal plenum. Using a slight
twisting motion, rotate the blower back and it will release.
Loosen Screws,
Do Not Remove
18
B. Exhaust Blower Replacement
1. Turn the dial control to the off position. Unplug the power
to the unit.
2. Remove the left side panel by loosening the two or three
bolts in the rear of the unit.
3. Disconnect 2 white wires from the white and blue wires of
the exhaust blower.
4. Remove the blower motor attached to a removable plate
on the exhaust blower. Depending on the model, use
a 1/4 inch socket, or 1/4 inch Nut Driver or #2 Phillips
Head screw driver to loosen the 6 screws in the keyhole
shaped holes and rotate the plate. It is only necessary to
loosen screws.
5. Remove the exhaust blower and gasket.
6. Check for degradation on the gasket and replace if
necessary using the gasket included in the kit.
7. Re-install in reverse order.
7083-171B • July 23, 2013
(877) 427- 3316

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents