LOCATING FIREpLACE

NOTICE:** Island (C) and Room Divider (D) installation is possible
as long as the horizontal portion of the vent system (H) does not
exceed 20 feet with a minimum vertical run of 8 feet. See details
in Venting Section.
*When you install your Direct Vent Fireplace in (D) Room divider or
(E) Flat on wall corner positions, a minimum of 6 inches clearance
must be maintained from the perpendicular wall and the front edge
of the appliance.
CABINET
CORNER
INSTALLATION
INSTALLATION
ISLAND
FLUSH WALL
INSTALLATION
INSTALLATION
ANGLED CORNER
INSTALLATION
ROOM DIVIDER
INSTALLATION
Figure 6
26927-8-0611
Page 9