Empire Comfort Systems DVP36DP31N-2 Installation Instructions And Owner's Manual page 15

Direct vent zero clearance gas fireplace heater
Hide thumbs Also See for DVP36DP31N-2:
Table of Contents

Advertisement

HoRIzonTAL onLY, STRAIGHT oUT THe bACK
"
A"
PIPE LENGTH
Nat models only
"A"
6"
5 1/8" to 6 1/2"
9"
8 1/8" to 9 1/2"
12" 11 1/8" to 12 1/2"
vERTICAL, 90° ELBOW TO
HORIzONTAL OUT THE WALL
90º ELBOW
"B"
Lp and Nat models
"A"
"B"
6"
11 1/4" to 12 3/4"
9"
14 1/4" to 15 3/4"
12"
17 1/4" to 18 3/4"
26927-8-0611
INSTALLATION (continued)
VENT CAP
WALL FIRESTOP/
THIMBLE
"B"
Figure 16
"A"
PIPE
LENGTH
VENT CAP
WALL FIRESTOP/
THIMBLE
"C"
"C"
4 3/4" to 6 1/4"
7 3/4" to 9 1/4"
10 3/4" to 12 1/4"
Figure 17
CORNER INSTALLATION vERTICAL, 90° ELBOW TO
HORIzONTAL OUT THE WALL
Lp and Nat models
Dim.
44 7/8" (114 cm)
A
31 3/4" (81 cm)
B
13 7/16" (34 cm)
C
63 7/16" (161 cm)
D
Figure 18
CoRneR InSTALLATIon HoRIzonTAL, 45° eLboW To
HORIzONTAL OUT THE WALL
WALL FIRESTOP/
THIMBLE
Nat models only
"A"
6"
4" to 5 1/2"
9"
6" to 7 1/2"
12"
9" to 10 1/2"
Figure 19
WALL FIRESTOP/
THIMBLE
VENT
CAP
DVP36
DVP36
"B"
Page 15