IPower 2x6
Now the Power Ports can be switched on and off using
number keys.
By pressing c you can check the network configuration and by
pressing Esc you can log out.

Temperature sensor

Connect the temperature sensor with the TEMP (f) connector on the
front of the device. When the connector is correctly instered the
recent temperature is displayed in the login window also in the
switching window and can be requested via SNMP.
The temperature sensor can be ordered as an optional extra,
please contact LINDY for more information.

Bootloader mode

To activate the bootloader mode of IPower 2x6 press the buttons "select" and "ok" on the front of the
Switch for three seconds. In bootloader mode it is possible to disable the password protection, to update
the firmware and to restore the default settings by running the program GBL_Conf.exe.
The bootloader mode of IPower 2x6 is indicated by "BOOTLDR" appended to the device name in the
program window of GBL_Conf.exe and by the alternating red and green blinking status led.
When in Bootloader mode you are unable to make changes to the switching state of any port.
To deactivate the bootloader mode press the buttons "select" and "ok" again for three seconds.

Firmware update

In order to update the firmware the program GBL_Conf.exe and the latest firmware are needed.
Activate the bootloader mode of the Switch and run the program GBL_Conf.exe. On the left side of the
program window all Switches that are in the network are listed.
Select the Switch you would like to update, click on Program Device → Firmware Update and select the
location of the new firmware.
To activate the new firmware, you need to deactivate the bootloader mode.

Technical information

Connections:
1 x Ethernet (RJ45)
1 x Serial Interface (D-SUB, RS232)
8 x Power Ports (IEC C13, max. 10A)
2 x Power supply inlet (IEC C20, max.16A)
Network connection: 10/100MBit Ethernet
Protocols: TCP/IP, HTTP, SNMP, Syslog
Operating temperatur: 0° C-50° C
Dimensions: 19'' / 1 rack unit
Weight: 2.3 kg