Setup
1. Set AllControl to OFF. Engage
gun trigger lock.
2. Unscrew tip and guard assembly
from gun.
3. Uncoil hose and connect one
end to gun. Use two
wrenches to tighten securely.
4. Connect other end of hose
to sprayer (a).
If hose is already connected, make sure connec-
tions are tight.
8
ti9168a
ti9204a
ti9203a
a
Priming and Flushing Storage
Fluid
Before you use your sprayer for the first time or begin a
new spraying project, you need to prime the sprayer and
flush the storage fluid out of the sprayer.
Oil- or Water-based Materials
When spraying water-based materials, flush
the system thoroughly with water.
When spraying oil-based materials, flush the
system thoroughly with mineral spirits or
compatible, oil-based flushing solvent.
To spray water-based materials after
spraying oil-based materials, flush the system
thoroughly with water first. The water flowing
out of prime tube should be clear and
solvent-free before you begin spraying the
water-based material.
To spray oil-based materials after spraying
water-based materials, flush the system
thoroughly with mineral spirits or a compatible
oil-based flushing solvent first. The solvent
flowing out of the prime tube should not contain
any water.
When flushing with solvents, ground gun. Read
Grounding and Electric Requirements, page 4.
To avoid fluid splashing back on your skin or
into your eyes, always aim gun at inside wall of
pail.
1. Make sure AllControl is set to
OFF and sprayer is unplugged.
2. Separate prime tube (smaller)
from Suction tube (larger).
Getting Started
ti9168a
ti9209a