DBD (disable block descriptor): Byte 1
When the DBD bit is 1, the target must not return the mode descriptor block in the Data In
phase. When this bit is 0, the target may or may not return the block.
This bit must be 0.
PC (page control): Byte 2
PC specifies the type of parameter returned, defined as follows:
Only 00 (current value) can be set. Other values cause the following error:
Status:
Sense key:
Page code: Byte 2
The page code specifies the page to be reported. The following are supported:
Page code
X'00'
X'01'
X'02'
X'03'
X'04' to X'3D'
X'3C'
X'3D'
X'3E'
X'3F'
Allocation length: Byte 4
The allocation length specifies the storage area allocated by the initiator for the mode sense
data in bytes.
0 means no data is transferred. This is not an error.
The target terminates the DATA IN phase when mode sense data for the number of bytes
specified in this field is transferred or when the tarnsfer of all valid mode sense data is
completed.
PC
Parameter type
00
Current value
01
Changeable value
10
Default
11
Saved value
B'00001' (CHECK CONDITION)
X'5' (ILLEGAL REQUEAT)
Description
Don't care (IGNORE)
Reserved
Not supported
Not supported
Reserved
Auto size detection
Lamp timer
Job separation sheet
Reserved
A.4 Commands