To Change Probe Calibration - Grill; To Change Platen Gap Set; To Change Instant-On Time; To Change Control Type - Garland XE24 Installation And Operation Manual

The garland electric xpress grill
Table of Contents

Advertisement

PROGRAMMING
5. Press
five, (5), times. "PROBE CAL – UPPER XXXF" is
displayed.
6. Use
or
to change the Probe Calibration to the
correct temperature measured with a pyrometer.* SEE
CALIBRATION REQUIREMENTS and CALIBRATION section.
7. Press
to save the changes.
8. Press
to return to "PROGRAMMING MODE SYSTEM
SETUP"
9. Press
again to exit.

To Change Probe Calibration - Grill:

1. Press and hold
for three, (3) seconds. "ENTER CODE" is
displayed.
2. Using the Product buttons, 0-9 enter the code, (1251).
"ENTER CODE **** " is displayed.
3. Press
to enter the Programming Mode.
"PROGRAMMING MODE MENU ITEMS" is displayed.
4. Press
two, (2) times. "PROGRAMMING MODE SYSTEM
SETUP" is displayed.
5. Press
six, (6), times. "PROBE CAL – GRILL XXXF" is
displayed.
6. Use
or
to change the Probe Calibration to the
correct temperature measured with a pyrometer.* SEE
CALIBRATION REQUIREMENTS and CALIBRATION Section.
7. Press
to save the changes.
8. Press
to return to "PROGRAMMING MODE SYSTEM
SETUP"
9. Press
again to exit.
*CALIBRATION REQUIREMENTS
The control software will beep to the user when it is
appropriate to calibrate. The control will allow calibration
provided the following conditions are met:
• Temperature is currently falling from a detected peak
of 360°F or higher.
• Temperature is falling and has fallen 2°F from a
detected peak that is within the 350-360°F range. (i.e.
calibration would be allowed at 355°F if the achieved
peak temperature was 357°F)
• Temperature is rising through the 350-360°F range as a
result of a heat on pulse of less than 30 seconds.
To Change Platen Top Set:
1. Press and hold
for three, (3) seconds. "ENTER CODE" is
displayed.
Part # 4517125 Rev. 2 (01/09/12)
continued
2. Using the Product buttons, 0-9 enter the code, (1251).
"ENTER CODE **** " is displayed.
3. Press
to enter the Programming Mode.
"PROGRAMMING MODE MENU ITEMS" is displayed.
4. Press
two, (2) times. "PROGRAMMING MODE SYSTEM
SETUP" is displayed.
5. Press
nine, (9) times. "PLATEN GAP SET +/- XX" is
displayed. (numbers will vary by grill)
6. Use
and
to change the Platen Gap Set to the
correct value.
7. Press
to save the changes.
8. Press
to return to "PROGRAMMING MODE MENU
ITEMS"
9. Press
again to exit.

To Change Instant-On Time:

1. Press and hold
for three, (3) seconds. "ENTER CODE" is
displayed.
2. Using the Product buttons, 0-9 enter the code, (1251).
"ENTER CODE **** " is displayed.
3. Press
to enter the Programming Mode.
"PROGRAMMING MODE MENU ITEMS" is displayed.
4. Press
two, (2) times. "PROGRAMMING MODE SYSTEM
SETUP" is displayed.
5. Press
ten, (10) times. "INSTANT ON TIME XX:XX" is
displayed. (numbers will vary by grill).
6. Use
and
to change the Instant on Time to the
desired value.
7. Press
to save the changes.
8. Press
to return to "PROGRAMMING MODE MENU
ITEMS"
9. Press
again to exit.

To Change Control Type:

Note: this must be verified if the control is changed, match
the new control to the grill.
1. Press and hold
for three, (3) seconds. "ENTER CODE" is
displayed.
2. Using the Product buttons, 0-9 enter the code, (1251).
"ENTER CODE **** " is displayed.
3. Press
to enter the Programming Mode.
Page 25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents