Symbologies
Code 93 — cont.

Code 93 Check Character Transmission

Enables/disables transmission of an optional Code 93 check character.
Code 93 Check Character Transmission = Enable

Code 93 Length Control

This feature specifies either variable length decoding or fixed length decoding for the
Code 93 symbology.
Variable Length —
may be set.
Fixed Length —
DEFAULT
Code 93 = Fixed Length
314
ENTER/EXIT PROGRAMMING MODE
For variable length decoding, a minimum and maximum length
For fixed length decoding, two different lengths may be set.
ENTER/EXIT PROGRAMMING MODE
Code 93 Check Character Transmission = Disable
DEFAULT
Code 93 Length Control = Variable Length