Symbologies
Standard 2 of 5 — cont.

Standard 2 of 5 Set Length 1

This feature specifies one of the barcode lengths for
Length 1 is the minimum label length if in
length if in
ters.
The length can be set from 1 to 50 characters.
Follow these instructions to set this feature:
1. Determine the desired character length (from 1 to 50). Pad the number with leading
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
3. Scan the barcode: SELECT STANDARD 2 OF 5 LENGTH 1 SETTING.
4. Scan the appropriate two digits from the keypad in
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
This completes the procedure. See
Table 33. Standard 2 of 5 Length 1 Setting Examples
STEP
ACTION
1
Desired Setting
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT STANDARD 2 OF 5 LENGTH 1 SETTING
Scan Two Characters From
4
Appendix E, Keypad
5
Scan ENTER/EXIT PROGRAMMING MODE
272
Mode. Length includes the barcode's check and data charac-
Fixed Length
zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
Mode.
the length setting which was determined in the steps above. You will hear a two-beep indi-
cation after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
NOTE
Mode.
01 Character
'0' and '1'
Standard 2 of 5 Length Control
Variable Length
Appendix E,
for some examples of how to set this feature.
Table 33
EXAMPLES
07 Characters
15 Characters
'0' and '7'
'1' and '5'
PowerScan
Mode, or the first fixed
Keypad, that represent
50 Characters
'5' AND '0'
PBT7100 Cordless