Component Leds - Fujitsu Primergy BX920 S4 Upgrade And Maintenance Manual

Primergy bx920 s4 server blade upgrade and maintenance manual
Hide thumbs Also See for Primergy BX920 S4:
Table of Contents

Advertisement

Basic hardware procedures
Ê Open the server blade as described in section
on page
56.
Ê Press the Indicate CSS button (1) to highlight defective components.

Component LEDs

I
LEDs C to G are visible from the frontside. All other LEDs are only visible
if the server blade cover has been removed. In order to access memory
LEDs (B), the air cowls need to be removed (see section
memory air cowls" on page
Indicator
A
Mezzanine card 1
B
Memory
Fabric 3/4
C
D
Fabric 2
E
Fabric 1
F
CSS
G
Global Error
SAS RAID
H
HDD module
50
181).
Status
Description
off
Mezzanine card 1 operational
orange on
Mezzanine card 1 failure
off
memory module operational
orange on
memory module failure
off
Fabric 3/4 no link
green flashing Fabric 3/4 link active
green on
Fabric 3/4 link established
off
Fabric 2 no link
green flashing Fabric 2 link active
green on
Fabric 2 link established
off
Fabric 1 no link
green flashing Fabric 1 link active
green on
Fabric 1 link established
off
System is ok
yellow
CSS error detected
flashing
yellow on
Prefailure event detected
off
No critical event
orange
Error detected (requires service intervention)
flashing
Prefailure event detected (requires service
orange on
intervention)
off
SAS RAID HDD module operational
orange on
SAS RAID HDD module failure
Upgrade and Maintenance Manual
"Opening the server blade"
"Handling of
BX920 S4

Advertisement

Table of Contents
loading

Table of Contents