Service Monitors (Filter, Uv And Humidifier Pad); Set Point Adjustment Limit; Thermostat Lock Code; Operating Your Thermostat - Braeburn 3020 Detailed User Manual

Premier series non-programmable thermostats
Hide thumbs Also See for 3020:
Table of Contents

Advertisement

Service Monitors
(Filter, UV and Humidifier Pad)
User Options 1, 2 and 3
There are three user selectable service monitors that will display
reminders for a required air filter, UV bulb or humidifier pad
replacement. The SERVICE segment flashes in the display
along with FILTER, UV or HUMID. When the service interval
has been reached, and required cleaning or replacement has
been performed, press the
RETURN
button to reset the
timer. Select OFF or a set number of days before the reminder
will appear.

Set Point Adjustment Limit

User Option 4
The Set Point Adjustment Limit will limit how much the
temperature can be adjusted from the current set point when
the thermostat is locked with security level 1(See Installer
Manual). This setting will not allow the user to override the
temperature past the selected limit amount of 1, 2 or 3 degrees
from the current set point. When the user reaches the adjustment
limit the screen will flash ADJ. A setting of 0 disables the
adjustment limit.
User Manual
Service Reminders
8

Thermostat Lock Code

User Option 5
The Thermostat Lock Code sets a 3-digit code that you may use at any time to lock or unlock the thermostat.
Setting the code in the user options mode does not activate the lock feature (See Locking/Unlocking Thermostat,
page 15). You may choose a 3-digit code with each digit being 0-9.

3 Operating Your Thermostat

Setting the SYSTEM Control Mode

The System Control has 5 modes of operation – AUTO, COOL, OFF, HEAT and EMER. The mode can be selected
by pressing the
SYSTEM
button to scroll through the different modes.
NOTE: Depending on how your thermostat was
configured, some system modes may not be available.
AUTO
The system will cycle between heating and cooling
automatically based on your program set points.
AUTO will be displayed with either HEAT or COOL.
COOL
Only your cooling system will operate.
OFF
Heating and cooling systems are off.
HEAT
Only your heating system will operate
EMER
Operates a backup heat source (Emergency Heat)
for heat pump systems only (Model 3220 only).