Trouble Codes; A. Trouble Codes List; B. Details Of Trouble Codes - Sharp AL-1661CS Service Manual

Digital multifunctional system
Hide thumbs Also See for AL-1661CS:
Table of Contents

Advertisement

SW103 No.5–No.8 Scan effective image area sub scan
rear edge image loss (OC)
Used to set image loss in scan image area.
Image loss on the rear edge in OC sub scan direction can be adjusted.
When the set value is increased, image loss is increased.
Setting is made in binary input in the increment of 16 lines.
Default: 144 lines
SW104 No.1–No.4 Scan effective image area main scan
left edge image loss (SPF back surface)
Used to set image loss in scan image area.
Image loss in SPF back surface main scan direction can be adjusted.
When the set value is increased, image loss is increased.
Setting is made in binary input in the increment of 24 dots.
Default: 96 dots
SW104 No.5–No.8 Scan effective image area main scan
right edge image loss (SPF back surface)
Used to set image loss in scan image area.
Image loss on the right edge in SPF back surface main scan direction
can be adjusted. When the set value is increased, image loss is
increased.
Setting is made in binary input in the increment of 24 dots.
Default: 96 dots
SW105 No.1–No.8 Scan magnification ratio adjustment
(OC main scan)
Used to set the main san magnification ratio in OC main scan.
Setting is made in binary input in the increment of 0.1%.
Default: 0%

8. Trouble codes

A. Trouble codes list

Main
Sub
code
code
E1
00
IMC communication trouble
10
IMC trouble
13
IMC flash ROM error
16
IMC DIMM memory read/write check error
81
IMC communication interface error (parity)
82
IMC communication interface error (Overrun)
84
IMC communication interface error (Framing)
E7
02
LSU trouble
10
Shading trouble (Black correction)
11
Shading trouble (White correction)
16
Abnormal laser output
F5
02
Copy lamp lighting abnormality
F6
10
FAX board trouble
H2
00
Thermistor open
H3
00
Heat roller high temperature detection
H4
00
Heat roller low temperature detection
L1
00
Feeding is not completed within the specified time after
starting feeding. (The scan head locking switch is locked)
L3
00
Scanner return trouble
L4
01
Main motor lock detection
L6
10
Polygon motor lock detection
U1
03
FAX board battery error
U2
04
EEPROM read/write error (Serial communication error)
11
Counter check sum error (EEPROM)
U9
99
Operation panel language error
Details of trouble
AL-1661CS TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 67
SW106 No.1–No.8 Scan magnification ratio adjustment
(OC sub scan)
Used to set the sub scan magnification ratio in OC sub scan.
Setting is made in binary input in the increment of 0.1%.
Default: 0%
SW107 No.1–No.8 Scan magnification ratio adjustment
(SPF back surface main scan)
Used to set the main scan magnification ratio in SPF back surface
scan.
Setting is made in binary input in the increment of 0.1%.
Default: 0%
SW108 No.1–No.8 Scan magnification ratio adjustment
(SPF back surface sub scan)
Used to set the sub scan magnification ratio in SPF back surface scan.
Setting is made in binary input in the increment of 0.1%.
Default: 0%
SW109 No.1–No.8 Print magnification ratio adjustment
(Main scan back surface)
Used to set the main scan magnification ratio in back surface print.
Setting is made in binary input in the increment of 0.1%.
Default: 0%
SW110 No.1–No.8 Print magnification ratio adjustment
(Sub scan back surface)
Used to set the sub scan magnification ratio in back surface print.
Setting is made in binary input in the increment of 0.1%.
Default: 0%

B. Details of trouble codes

Main
Sub
code
code
E1
00
Content IMC communication trouble
Detail
An abnormality occurs in communication
between the CPU and the IMC.
Cause
IMC – CPU signal line abnormality
IMC Memory defect/data abnormality
Check
Replace the MCU PWB with new one.
and
remedy
10
Content IMC trouble
Detail
An abnormality occurs in the IMC.
Cause
USB chip error/CODEC error on the IMC.
Check
Replace the MCU PWB with a new one.
and
remedy
13
Content IMC flash ROM error
Detail
An abnormality occurs in the IMC flash ROM.
Cause
IMC abnormality
Check
Replace the MCU PWB with a new one.
and
If downloading of the program is abnormally
remedy
terminated, it may cause an error. Download
the program again to avoid this.
Details of trouble

Hide quick links:

Advertisement

Table of Contents
loading