Sharp AL-1661CS Service Manual page 92

Digital multifunctional system
Hide thumbs Also See for AL-1661CS:
Table of Contents

Advertisement

Main
Sub
Contents
code
code
43
05
Fusing temperature setting
in duplex copy (FU TEMP
DPLX)
09
Postcard size paper fusing
control setting (FU CTR P-
CARD) (Japan model only)
11
Postcard size paper fusing
temperature setting (FU
TEMP P-CARD) (Japan
model only)
14
Fusing start temperature
setting (FU TEMP START)
[Function]
In the case of duplex copy, the shift temperature set with this test command is applied to the fusing
temperature.
When this test command is executed, the current set code number is displayed.
Enter the desired code number and press [ENTER/START] key to save the setting.
Code
Shift temperature (°C)
0
1
2
3
4
5
6
7
8
9
[Operation]
The operation is similar to test command 21-01.
[Function]
When this test command is executed, the current set code number is displayed.
Enter the desired code number and press [ENTER/START] key to save the setting.
Code
Shift temperature (°C)
0
1
Setting" is default for Japan. However, there is no schedule for production of the Japan model.
[Operation]
The operation is similar to test command 21-01.
[Function]
When this test command is executed, the current set code number is displayed.
When [ / /10KEY] key is pressed, setting is changed. When [ENTER/START] key is pressed, set-
ting is written into the EEPROM. The machine goes into the sub code entry standby mode.
Code
Shift temperature (°C)
0
1
2
3
4
5
6
7
8
Applied only to the Japan model. However, there is no schedule to produce the Japan model. Set-
ting is reflected only when ON with test command 43-09.
[Operation]
The operation is similar to test command 21-01.
[Function]
When this test command is started, the currently set code number is displayed.
Press [ / /10KEY] to switch the setting, and press [ENTER/START] key to save it to the EEPROM.
The machine goes to the sub code entry standby mode.
Code
0
1
2
3
4
5
6
7
8
[Operation]
The operation is similar to test command 21-01.
AL-1661CS TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 16
Details of function/operation
Remark
±0
Default
-8
-6
-4
-2
±0
+2
+4
+6
+8
Display item
Cancel
OFF
Setting
ON
Remark
160
165
170
175
180
185
190
195
Default
200
Set temperature (°C)
Remark
160
165
170
175
180
185
190
195
Default
200
Remark