Rs-232 Word Length: Data Bits, Stop Bits, And Parity; Rs-232 Handshaking - Honeywell 2020 User Manual

Cordless system
Hide thumbs Also See for 2020:
Table of Contents

Advertisement

RS-232 Word Length: Data Bits, Stop Bits, and Parity

Data Bits sets the word length at 7 or 8 bits of data per character. If an applica-
tion requires only ASCII Hex characters 0 through 7F decimal (text, digits, and
punctuation), select 7 data bits. For applications which require use of the full
ASCII set, select 8 data bits per character. Default = 8.
Stop Bits sets the stop bits at 1 or 2. Default = 1.
Parity provides a means of checking character bit patterns for validity.
Default = None.
7 Data, 1 Stop, Parity Even
7 Data, 1 Stop, Parity Odd
7 Data, 2 Stop Parity None
8 Data, 1 Stop, Parity Even
8 Data, 1 Stop, Parity Odd

RS-232 Handshaking

RS-232 Handshaking allows control of data transmission from the image scan-
ner using software commands from the host device. CTS/RTS operates in
mode 2. When this feature is turned Off , no data flow control is used. When
Data Flow Control is turned On , the host device suspends transmission by
sending the XOFF character (DC3, hex 13) to the image scanner. To resume
2 - 10
7 Data, 1 Stop, Parity None
7 Data, 2 Stop, Parity Even
7 Data, 2 Stop, Parity Odd
* 8 Data, 1 Stop, Parity None