5. Read the voltmeter on the front panel of the generator
(Figure 20) and verify that 240 VAC is present at the
240V twist-lock receptacle. Using an external voltmeter
verify that 120V is present at the 120V twist-lock and
GFCI duplex receptacles.
Figure 20. 60 Hz Output Receptacles
When the full power switch is in the 240
volt (down) position, you can take up to
NOTE
half of the rated power of the generating
set at 120 volts from the GFCI duplex
receptacle and up to half of the rated power of the set at 120
volts from the 120V twist-lock receptacle; or full rated power
of the genset at 240 volts from the 240V twist-lock
receptacle.
When using a combination of dual
receptacles, total load should not exceed
NOTE
the rated capacity of the generator.
Connecting the Load
1. If small wattage power tools are required, connect them
to the 60 Hz output receptacles at this time.
GA-3.6H SERIES A.C. GENERATORS — OPERATION & PARTS MANUAL — REV. #0 (11/01/05) — PAGE 25
GA-3.6H Series— GENERATOR OPERATION/SHUTDOWN
Stopping the Engine
1. Place the main circuit breaker (Figure 21) in the OFF
position.
Figure 21. Main Circuit Breakers (Off)
2. Place the idle control switch (Figure 22) in the OFF
position.
Figure 22. Idle Control Switch (Off)
3. Let the engine run at idle with no load for 2-3 minutes.
4. To shut-down the engine, place the generator's operation
switchg(Figure 23) in the OFF
Figure 23. Generator Operation Switch (Off)
5. Place the engine fuel valve lever (Figure 24) to the "OFF"
position. "
Figure 24. Engine Fuel Valve Lever (OFF Position)
6. Remove all loads from the generator.
position.e