6. If the engine has started, slowly return the choke lever
(Figure 11) to the "OPEN" position. If the engine has not
started repeat steps 1 through 5.
7. Before the generator is placed into operation, run the engine
for 3-5 minutes. Check for abnormal smells, fuel leaks, and
noises that would associate with lose components.
8. Place the idle control switch (Figure 14) in the "OFF"
(down) position. This will allow the engine speed to run
at speed about 3600 RPM's
Figure 14. Idle Control Switch (Off)
NOTE
the generators will run at idle speed (2200 RPM's) until a load is
applied, at that time the engine speed will increase to 3600
RPM's as long as the load is being applied. When the load is not
in use, the engine speed will drop back to the idle mode after
about 3 seconds.
Figure 15. Idle Control Switch (On)
60 Hz Operation
1. Place main circuit breaker (Figure 16) in the ON position.
Figure 17. Main Circuit Breaker (ON)
PAGE 24 — GA-3.6H SERIES A.C. GENERATORS — OPERATION & PARTS MANUAL — REV. #0 (11/01/05)
Placing the idle control switch in
the OFF position (Figure 14) allows
the engine to operate at a maximum
speed of about 3600 RPM's. When
the idle control switch is placed in
the up position (ON) (Figure 15),
2. Place the full power switch (Figure 17) in the 120V
position (up).
Figure 17. Full Power Switch 120 V Position (Up)
When the full power switch is in the 120 V
position, the 240V twist-lock receptacle
NOTE
cannot be used.
3. Read the voltmeter on the front panel of the generator
(Figure 18) and verify that120 VAC is present at the
120V twist-lock and GFCI duplex receptacles. For
additional verification of voltage, an external voltmeter
can be used to measure the output voltage as shown in
Figure 18.
Figure 18. 120 V and GFCI Receptacles
4. Place the full power switch (Figure 19) in the 240V
position (down).
Figure 19. Full Power Switch 240/120 V Position (Down)