Installation Instructions Downdraft Raised Vent Models: ERV36-ER, ERV48-ER Use these downdraft raised vents only with approved Dacor ® appliances. See the installation instructions for the particular appliance model being installed to determine suitability. Part No. 103106 Rev. H...
WARNING ating this or any other appliance. Always contact the Dacor Customer Service Team Hazards 0r Unsafe practices that COULD result in severe about problems and conditions that you don't under- personal injury or death.
A qualified service t0mer to have it replaced with a dedicated, properly technician should perform all other service. Contact the Dacor Customer Service Team for examination, repair or adjustment. • Keep all packaging materials away from children.
The vent system consists of the raised vent itself and a sin- department for further information. gle Dacor approved remote or in-line blower (see page 6). The electric outlet for the raised Vent should be installed only by a licensed electrician.
Page 7
The raised vent exhaust may be configured to vent through the back, the bottom or through one of the Backsplash ", sides. The maximum allowable duct run must be taken __ifl Notch into consideration when determining the layout. See Planning the Duct Work for further details. Refer to the range installation instructions for the mini- mum cutout dimensions specific to the particular range Countertop...
DO NOT install more than one blower to increase the length of the duct run. Even small differences between blower air flow rates can greatly reduce the air draw by the raised vent. You must install one of the Dacor remote or in-line blower When connecting the duct work to the back of the unit, models listed below for the raised vent to operate properly.
Page 9
On side exhaust installations, allow five inches of space on the side for the ADT2 exhaust transition plus addi- tional space for the duct attached to it (X). Make sure duct work does not interfere with floor joists ATD2\ or wall studs. •...
Cut and remove the foil material inside the knock-out Installation Preparation hole. If you fail to remove the foil, the vent will not work. If the unit will vent through the bottom or side: Verify Package Contents • Attach the supplied ATD2 transition to exhaust •...
Page 11
Gently slide the vent into the rear of the countertop cut- Installing the Blower and Ducts out with the electrical access panel toward the front. Install the remote or in-line blower according to the blower installation instructions. Install the duct work according to the Installation Specifications.
Page 12
Electrical Installation Run the wiring/conduit line used to supply power from the raised vent to the blower parallel to the duct work. [_ WARNING Make sure the raised vent power plug is disconnected from the electrical outlet. • ELECTRIC SHOCK HAZARD - Do not connect the Remove the cover from the raised vent electrical raised vent power plug to the electrical outlet until access panel.
Page 13
REMP series remote blower Connect wires/conduit according to remote blower installation instructions Raised vent Range See ERV electrical access panel on facing page Floor Wiring/conduit from ERV to remote blower Example of Installation with Bottom Exhaust (Side View) Range Installation Install the range according to the range installation instructions.
3226. Be sure to have the model and serial numbers avail- able when you call. See the label on the front of the raised vent. Dacor is not responsible for the cost of correcting problems resulting from a faulty installation. 12 c_acar...
DOWN UMIT SWITCH UMIT SWITCH SNORKEL SWITCH COMNO NC BLUE CHASSIS GROUND STUD BLUE RELAY REMOTEPOT NO I N COM I_2 N2 NI GND GND I__I L__I L__I BLOWER POWER GROUND SPEED CONTRLoL OUTPUT INPUT ORNG ctacor...