Installation
Instructions
Downdraft
Raised Vent
Models
ERV3015 and ERV3615
Includes
installation instructions for optional
cabinet blower (Dacor model CABP3)
Use these downdraft
raised vents only with approved
Dacor ® appliances.
See the installation
instructions for the particular
appliance
model being
installed to determine
suitability.
Pa_ No. 107000
Rev. D

Advertisement

Table of Contents
loading

Summary of Contents for Dacor ERV3015

  • Page 1 Installation Instructions Downdraft Raised Vent Models ERV3015 and ERV3615 Includes installation instructions for optional cabinet blower (Dacor model CABP3) Use these downdraft raised vents only with approved Dacor ® appliances. See the installation instructions for the particular appliance model being installed to determine suitability.
  • Page 2: Table Of Contents

    Monday - Friday 6:00 AoMoto 5:00 P.M. Pacific Time your Dacor ®dealer or the Dacor Customer Service Team. Web site: www.dacor.com For repairs to Dacor appliances under warranty call the Dacor Dacor Distinctive Service (for repairs under warranty Distinctive Service line. Whenever you call, have the model only) and serial number of the appliance ready.
  • Page 3: Important Safety Instructions

    I]_ WARNING ating this or any other appliance. • Always contact the Dacor Customer Service Team Hazards or unsafe pract!ces that COULD result in severe about problems and conditions that you don't under- personal injury or death.
  • Page 4: General Safety Precautions

    -Observe all governing c0des an d ordinances during Planning and installati0n. Contact your local building with these installation instructions, the Dacor range/ department for further information: cooktop installation instructions and the blower instal- lation instructions. Improper installation, adjustment, The electric Outlet for the ra!sed vent shoul d be...
  • Page 5: Product Dimensions

    (5.6cm) I ", Number Width Width 5/16" (8 mm) 2 1/8" cap with thick stiffener (5.4 cm) vent clown ERV3015 30" (76.2 cm) 27 3/8" (69.5 cm) ERV3615 36" (91.4 cm) 33 3/8" (84.8 cm) across back (7.6 cm) _9/16" 3/8"...
  • Page 6: Installation Specifications

    Planning the installation General System Layout The vent system consists of the raised vent itself and a sin- gle Dacor approved cabinet blower, remote blower or in-line blower (see facing page for examples). WARNING Countertop overhang Vertical • Failure to install an approved blower or proper duct...
  • Page 7 Backsplash Front of unit Cooktop Cabinet blower Raised vent Blower wiring access hole CABP3 Connection cabinet blower cabinet blower Wall Blower wiring _XXXXXXXXX Wall cap Connection access hole remote/in-line 3 1/4"x 10"--.4P blower 90 ° elbow Electrical Layout 12" min. (30.5 cm) REMP series remote blower...
  • Page 8: Planning The Duct Work

    2"x 16", connects to side or bottom exhaust You must install one of the Dacor blower models listed 5" (12.7 cm) on raised vent below for the raised vent to operate properly. See the blow- er installation instructions for directions.
  • Page 9 6_1/4" 1 1/8"_ (15i9 cm) _® ®_ Front of unit (2.9 cm) ® ¢@ (_) Rear exhaust knock-out (3 ¼" x 10") Vertical center line of rear exhaust knock out lines up with vertical center line of chassis ® Bottom exhaust knock-out (1 5/8"...
  • Page 10 Exhaust Locations and Dimensions for CABP3 Cabinet Blower installations Model 12 1/8" 5 5/8" 1 3/4" ERV3015 (30.7 cm) (14.4 cm) (4.4 cm) > 9 3/4" 8" 4 1/4" ERV3615 (24.8 cm) (20.3 cm) (10.8 cm) Raised vent Countertop center line 26 1/4"...
  • Page 11 Calculating the Maximum Duct Run Length Duct Work Design Tips • For optimal performance, consult a qualified HVAC • Wherever possible, reduce the number of transitions specialist when designing the duct system. and turns to as few sharp angles as possible. Two staggered 45 °...
  • Page 12: Installation Preparation

    • Insulation foam (tape) Rear knock-out with metal cross overs Installation with CABP3 blower requires Dacor adapter kit _ shown # AERVCAB. Kit includes adapter, wiring diagram label (PN 106770), 3 wing nuts (PN 83035), 3 flat washers (PN 83008) and 6 lock washers (PN83340).
  • Page 13: Installing The Raised Vent In The Cutout

    Installation Preparation for Raised Vent with Installing the Raised Vent in the CABP3 Cabinet Blower: Cutout You must remove the raised vent front cover so that the AERVCAB cabinet blower adapter can be installed. To Cut a hole in the cabinet to allow the duct work to pass do so, remove and retain the three (3) wing nuts and through to the floor or wall for the planned duct system three (3) flat washers on the front of the unit.
  • Page 14 Cabinet Blower Installation ILHSF or REMP Series Blower Installation If using cabinet blower (model CABP3): If using a ILHSF or REMP series blower, install it according to the blower installation instructions. Locate the wiring diagram label included with the Duct Work Installation adapter kit.
  • Page 15 Wires to powerplug. Match wirecolors to Pre-wired a tfactory. terminals as shown. Donotmodify. Front o f raised vent GREEN Attachground wire Blower p ower wiring/conduit. Connect otherendofwires as shown to blower t erminal b lock. blower w iring accesshole WireColors: Black= Line(L),White= Neutral ( N), Green= Ground (Gnd) Electrical installation...
  • Page 16: Verifying Proper Operation

    Dacor Distinctive Service at (877) 337-3226. Be sure to have all model and serial numbers from the product data labels for the raised vent and the blower available when you call. Dacor is not responsible for the cost of correcting problems caused by a faulty installation. 14 da=_r...
  • Page 17: Ervxx15 Raised Vent Wiring Diagram

    ERVxxl 5 Raised Vent Wiring Diagram DOWN UMIT SWITCH UMIT SWITCH SNORKEL SWITCH COMNO NC BLUE CHASSIS GROUND STUL BLUE RELAY REMOTE POT I_2 N2 COM NO GNDI o oj 1__1 I__J [__I BLOWER POWER GROUND SPEEDCONTROL OUTPUT INPUT ORNG CABP3 Cabinet Blower Ratings CABP3 Blower Performance...
  • Page 18 da=_r...