Dacor ERV3615 Installation Instructions Manual
Dacor ERV3615 Installation Instructions Manual

Dacor ERV3615 Installation Instructions Manual

Downdraft raised vent
Hide thumbs Also See for ERV3615:

Advertisement

Installation
Instructions
Downdraft
Raised Vent
Model
ERV3615
Use these downdraft
raised vents only with approved
Dacor ® appliances.
See the installation
instructions for the particular
appliance
model being
installed to determine
suitability.
Pa_ No. 107000
Rev. A

Advertisement

Table of Contents
loading

Summary of Contents for Dacor ERV3615

  • Page 1 Installation Instructions Downdraft Raised Vent Model ERV3615 Use these downdraft raised vents only with approved Dacor ® appliances. See the installation instructions for the particular appliance model being installed to determine suitability. Pa_ No. 107000 Rev. A...
  • Page 2: Table Of Contents

    Monday - Friday 6:00 a.m. to 5:00 p.m. Pacific Time your Dacor ®dealer or the Dacor Customer Service Team. Web site: www.Dacor.com For repairs to Dacor appliances under warranty call the Dacor Dacor Distinctive Service (for repairs under warranty Distinctive Service line. Whenever you call, have the model only) and serial number of the appliance ready.
  • Page 3: Important Safety Instructions

    [_ WARNING ating this or any other appliance. • Always contact the Dacor Customer Service Team HaZards oi unsafe practices that COULD result in Severe about problems and conditions that you don't under- personal injury or death.
  • Page 4: General Safety Precautions

    Contact Cut or remOVe the th![d (ground)prong from the Dacor Customer Service Team for examination, powei repair or adjustment. Keep all packaging materials away from children. Plastic bags can cause suffocation. Use a power cord that is frayed or damaged:...
  • Page 5: Product Specifications

    Product Dimensions Tolerances: +1/16" (+1.6 mm) unless otherwise stated _" 2 3/16" " ,, s" (5.6cm) I ", A - Top Cap B - Chassis 2 1/8" I 5/16" (8 mm) Width Width thick stiffener (5.4 cm) Top cap with vent down across back 36"...
  • Page 6: Installation Specifications

    The vent system consists of the raised vent itself and a single sides. Allow room for the exhaust duct coming out Dacor approved remote or in-line blower (see page 6). of the unit. See Planning the Duct Work for further...
  • Page 7 Vertical non-combustible surface rear wall Notches required for some rasied vent installations, see cooktop installation instructions See the cooktop installation instructions for exact countertop and cabinet dimensions . Flush with back side ..of cabinet front Cooktop Cabinet/Countertop Cutout = Top View REMP series remote blower 3 ¼"...
  • Page 8: Planning The Duct Work

    DO NOT install more than one blower to increase the length of the duct run. Even small differences between blower air flow rates can greatly reduce the air draw by the raised vent. You must install one of the Dacor remote or in-line blower When connecting the duct work to the back of the unit, the customer must supply a 3 ¼"...
  • Page 9 On side exhaust installations, allow five inches of space on the side for the ADT2 exhaust transition plus addi- tional space for the duct attached to it (X). Make sure duct work does not interfere with floor joists or wall studs. •...
  • Page 10: Installation Preparation

    Cut and remove the foil material inside the knock-out Installation Preparation hole. If you fail to remove the foil, the vent will not work. If the unit will vent through the bottom or side: Package Contents Attach the supplied ATD2 transition to exhaust Product literature location with the provided sheet metal screws.
  • Page 11 Gently slide the vent into the rear of the countertop cut- Blower Ducts clnd installing out with the electrical access panel toward the front, Install the remote or in-line blower according to the blower installation instructions. Install the duct work according to the Installation Specifications section.
  • Page 12 Electrical Installation Run the wiring/conduit line used to supply power from the raised vent to the blower parallel to the duct work. [_ WARNING Make sure the raised vent power plug is disconnected from the electrical outlet. • ELECTRIC SHOCK HAZARD - Do not connect the Remove the cover from the raised vent electrical raised vent power plug to the electrical outlet until access panel.
  • Page 13 REMP16 remote blower Connect wires/conduit according to remote blower installation instructions Raised vent Cooktop See Raised Vent Electrical Access Panel on facing page Floor )3?)))_))g))))?_))?Ji)_?)???_ Wiring/conduit from raised vent to remote blower Example of installation with Bottom Exhaust (Side View) Cooking AppJiance InstaJJation Install the cooking appliance according to its installation instructions.
  • Page 14: Verifying Proper Operation

    Dacor Distinctive Service at (877) 337-3226. Be sure to have all model and serial numbers from the product data labels for the raised vent and the blower available when you call. Dacor is not responsible for the cost of correcting problems caused by a faulty installation. 12 dater...
  • Page 15: Wiring Diagram

    DOWN UMIT SWITCH UMIT SWITCH SNORKELSWITCH COM NO NC BLUE CHASSIS GROUND sTuD__@@ BLUE RELAY REMOTEPOT GNDl o o 1 1__1 I__I POWER BLOWER GROUND SPEEDCONTROL INPUT OUTPUT ORNG dacDr...
  • Page 16 ® Family Owned American Made The Life of the Kitchen? bacor • 600 Anton Blvd. Suite 1000 Costa Mesa, CA 92626 • Phone: (800) 793-0093 • Fax: (626)403-3130 • www.bacor.com...

Table of Contents