Downdraft Raised Vent
Models ERV3015 and ERV3615
Use these downdraft raised vents only with approved Dacor
appliances.
®
See the installation instructions for the particular appliance model being
installed to determine suitability.
Part No. 107000 Rev.B

Advertisement

Table of Contents
loading

Summary of Contents for Dacor ERV3015

  • Page 1 Installation Instructions Downdraft Raised Vent Models ERV3015 and ERV3615 Use these downdraft raised vents only with approved Dacor appliances. ® See the installation instructions for the particular appliance model being installed to determine suitability. Part No. 107000 Rev.B...
  • Page 2: Table Of Contents

    Dacor ® dealer or the Dacor Customer Service Team. Web site: www.dacor.com For repairs to Dacor appliances under warranty call the Dacor Dacor Distinctive Service (for repairs under warranty Distinctive Service line. Whenever you call, have the model only) and serial number of the appliance ready.
  • Page 3: Important Safety Instructions

    WARNING ating this or any other appliance. • Always contact the Dacor Customer Service Team Hazards or unsafe practices that COULD result in severe about problems and conditions that you don’t under- personal injury or death.
  • Page 4: General Safety Precautions

    A qualified service cumstances: technician should perform all other service. Contact ♦ Cut or remove the third (ground) prong from the the Dacor Customer Service Team for examination, power cord. repair or adjustment. ♦ Use an adapter plug.
  • Page 5: Product Specifications

    2 1/8 ” Model 5/16” (8 mm) Top cap with Width Width (5.4 cm) thick stiffener vent down ERV3015 30” (76.2 cm) 27 3/8" (69.5 cm) across back ERV3615 36” (91.4 cm) 33 3/8" (84.8 cm) 3/16” (5 mm) 3”...
  • Page 6: Installation Specifications

    The vent system consists of the raised vent itself and a single sides. Allow room for the exhaust duct coming out Dacor approved remote or in-line blower (see page 6). of the unit. See Planning the Duct Work for further details.
  • Page 7 Installation Specifications Backsplash Countertop overhang Vertical non-combustible surface rear wall Notches required for some rasied vent installations, see cooktop installation instructions See the cooktop installation instructions for exact countertop and cabinet dimensions Flush with back side of cabinet front Cooktop Cabinet/Countertop Cutout - Top View REMP series remote blower 3 ¼”...
  • Page 8: Planning The Duct Work

    • When connecting the duct work to the back of the unit, You must install one of the Dacor remote or in-line blower the customer must supply a 3 ¼” X 10” rectangular models listed below for the raised vent to operate properly.
  • Page 9 Installation Specifications • On side exhaust installations, allow five inches of space on the side for the ADT2 exhaust transition plus addi- tional space for the duct attached to it (X). 5” • Make sure duct work does not interfere with floor joists ATD2 or wall studs.
  • Page 10: Installation Instructions

    Installation Instructions Installation Preparation 2. Cut and remove the foil material inside the knock-out hole. If you fail to remove the foil, the vent will not work. 3. If the unit will vent through the bottom or side: Verify Package Contents •...
  • Page 11 Installation Instructions 5. Gently slide the vent into the rear of the countertop cut- Installing the Blower and Ducts out with the electrical access panel toward the front. 1. Install the remote or in-line blower according to the blower installation instructions. 2.
  • Page 12: Electrical Installation

    Installation Instructions 1. Run the wiring/conduit line used to supply power from Electrical Installation the raised vent to the blower parallel to the duct work. WARNING 2. Make sure the raised vent power plug is disconnected from the electrical outlet. • ELECTRIC SHOCK HAZARD - Do not connect the 3.
  • Page 13 Installation Instructions REMP16 remote blower Connect wires/conduit according to remote blower installation instructions Raised vent Cooktop See Raised Vent Electrical Access Panel on facing page Floor Wiring/conduit from raised vent to remote blower Example of Installation with Bottom Exhaust (Side View) Cooking Appliance Installation Install the cooking appliance according to its installation instructions.
  • Page 14: Verifying Proper Operation

    Dacor Distinctive Service at (877) 337-3226. Be sure to have all model and serial numbers from the product data labels for the raised vent and the blower available when you call. Dacor is not responsible for the cost of correcting problems caused by a faulty installation.
  • Page 15: Wiring Diagram

    Wiring Diagram DOWN LIMIT SWITCH LIMIT SWITCH SNORKEL SWITCH BLUE CHASSIS GROUND STUD BLUE RELAY REMOTE POT BLOWER POWER GROUND SPEED CONTROL OUTPUT INPUT ORNG...