Installation Instructions
Downdraft Raised Vent
Models ERV3015 and ERV3615
Includes installation instructions for optional cabinet blower (Dacor model CABP3)
Use these downdraft raised vents only with approved Dacor
appliances.
®
See the installation instructions for the particular appliance model being
installed to determine suitability.
Part No. 107000 Rev. D

Advertisement

Table of Contents
loading

Summary of Contents for Dacor ERV3015

  • Page 1 Installation Instructions Downdraft Raised Vent Models ERV3015 and ERV3615 Includes installation instructions for optional cabinet blower (Dacor model CABP3) Use these downdraft raised vents only with approved Dacor appliances. ® See the installation instructions for the particular appliance model being installed to determine suitability.
  • Page 2: Table Of Contents

    Dacor ® dealer or the Dacor Customer Service Team. Web site: www.dacor.com For repairs to Dacor appliances under warranty call the Dacor Dacor Distinctive Service (for repairs under warranty Distinctive Service line. Whenever you call, have the model only) and serial number of the appliance ready.
  • Page 3: Important Safety Instructions

    WARNING ating this or any other appliance. • Always contact the Dacor Customer Service Team Hazards or unsafe practices that COULD result in severe about problems and conditions that you don’t under- personal injury or death.
  • Page 4: General Safety Precautions

    • Observe all governing codes and ordinances during • Install or locate this appliance only in accordance planning and installation. Contact your local building with these installation instructions, the Dacor range/ department for further information. cooktop installation instructions and the blower instal- lation instructions.
  • Page 5: Product Dimensions

    2 1/8 ” Number Width Width 5/16” (8 mm) Top cap with (5.4 cm) thick stiffener vent down ERV3015 30” (76.2 cm) 27 3/8” (69.5 cm) across back ERV3615 36” (91.4 cm) 33 3/8” (84.8 cm) 3/16” (5 mm) 3”...
  • Page 6: Installation Specifications

    Installation Specifications Planning the Installation General System Layout Backsplash The vent system consists of the raised vent itself and a sin- gle Dacor approved cabinet blower, remote blower or in-line blower (see facing page for examples). WARNING Countertop overhang Vertical • Failure to install an approved blower or proper duct...
  • Page 7 Installation Specifications Backsplash Front of unit Cooktop Cabinet blower Raised vent Blower wiring access hole CABP3 Connection to cabinet blower cabinet blower Wall Floor Blower wiring Wall cap Connection to access hole remote/in-line 3 1/4” x 10” blower 90° elbow Electrical Layout 12”...
  • Page 8: Planning The Duct Work

    2” x 16”, connects to 5" side or bottom exhaust You must install one of the Dacor blower models listed (12.7 cm) on raised vent below for the raised vent to operate properly. See the blow- er installation instructions for directions.
  • Page 9 Installation Specifications 6 1/4" (15.9 cm) 1 1/8"   (2.9 cm) Front of unit Motor cover    3”       Rear exhaust knock-out (3 ¼” x 10”)  Vertical center line of rear exhaust knock out lines up with vertical center line of chassis ...
  • Page 10 Installation Specifications Exhaust Locations and Dimensions for CABP3 Cabinet Blower Installations Model Cooktop 12 1/8” 5 5/8” 1 3/4” ERV3015 (30.7 cm) (14.4 cm) (4.4 cm) 9 3/4” 8” 4 1/4” ERV3615 (24.8 cm) (20.3 cm) (10.8 cm) CABP3 Raised vent...
  • Page 11 Installation Specifications Calculating the Maximum Duct Run Length Duct Work Design Tips • For optimal performance, consult a qualified HVAC • Wherever possible, reduce the number of transitions specialist when designing the duct system. and turns to as few sharp angles as possible. Two staggered 45°...
  • Page 12: Installation Instructions

    • Insulation foam (tape) Rear knock-out with metal cross overs Installation with CABP3 blower requires Dacor adapter kit shown # AERVCAB. Kit includes adapter, wiring diagram label (PN 106770), 3 wing nuts (PN 83035), 3 flat washers (PN 83008) and 6 lock washers (PN83340).
  • Page 13: Installing The Raised Vent In The Cutout

    Installation Instructions Installing the Raised Vent in the Installation Preparation for Raised Vent with CABP3 Cabinet Blower: Cutout 1. You must remove the raised vent front cover so that the AERVCAB cabinet blower adapter can be installed. To 1. Cut a hole in the cabinet to allow the duct work to pass do so, remove and retain the three (3) wing nuts and through to the floor or wall for the planned duct system three (3) flat washers on the front of the unit.
  • Page 14: Duct Work Installation

    Installation Instructions Cabinet Blower Installation ILHSF or REMP Series Blower Installation If using cabinet blower (model CABP3): If using a ILHSF or REMP series blower, install it according to the blower installation instructions. 1. Locate the wiring diagram label included with the adapter kit.
  • Page 15 Installation Instructions Wires to power plug. Match wire colors to Pre-wired at factory. terminals as shown. Do not modify. Front of raised vent BLACK WHITE CABP3 cabinet blower Electrical connection Electrical access from raised vent, panel match Wire Colors GREEN Blower power wiring/conduit.
  • Page 16: Verifying Proper Operation

    Dacor Distinctive Service at (877) 337-3226. Be sure to have all model and serial numbers from the product data labels for the raised vent and the blower available when you call. Dacor is not responsible for the cost of correcting problems caused by a faulty installation.
  • Page 17: Ervxx15 Raised Vent Wiring Diagram

    Technical Data ERVxx15 Raised Vent Wiring Diagram DOWN LIMIT SWITCH LIMIT SWITCH SNORKEL SWITCH BLUE CHASSIS GROUND STUD BLUE RELAY REMOTE POT BLOWER POWER GROUND SPEED CONTROL OUTPUT INPUT ORNG CABP3 Cabinet Blower Ratings CABP3 Blower Performance CABP3 Cabinet blower Airflow* Nominal 600 CFM Actual...
  • Page 18 Notes...
  • Page 20 Dacor ● 14425 Clark Avenue, City of Industry, CA 91745 ● Phone: (800) 793-0093 ● Fax: (626) 403-3130 ● www.dacor.com...