Crispening Adjustment (4:3); Level Depandent Adjustment (4:3) - Sony DNW-7 Maintenance Manual

Hide thumbs Also See for DNW-7:
Table of Contents

Advertisement

6-14. Crispening Adjustment (4:3)

Preparation
. On the setting menu, set as follows.
PAGE
: FUNCTION 1/2
ITEM
: DETAIL
. OUTPUT/DCC switch (inside panel)
. Shoot a gray-scale chart (4:3) in the full underscan's
picture frame.
: 1 Lens IRIS
Setting point
: A = 100 ± 2 IRE (NTSC)
Spec.
A = 700 ±14 mV (PAL)
Adjustment procedure
Equipment
: Black and white monitor
Test point
: TEST OUT connector
1. On the setting menu, adjust as follows.
PAGE
: LEVEL 1
ITEM
: CRISPENING
Spec.
: Reduce the noise on the screen to a
permissible level.
DNW-7/90/90WS
4:3 mode
ON
CAM/ON
A

6-15. Level Depandent Adjustment (4:3)

Preparation
. On the setting menu, set as follows.
PAGE
: FUNCTION 1/2
ITEM
: DETAIL
ITEM
: TEST OUT
. OUTPUT/DCC switch (inside panel)
. Shoot a gray-scale chart (4:3) in the full underscan's
picture frame.
: 1 Lens IRIS
Setting point
: A = 100 ± 2 IRE (NTSC)
Spec.
A = 700 ±14 mV (PAL)
Adjustment procedure
Test point: TEST OUT connector
1. On the setting menu, adjust as follows.
PAGE
: LEVEL 1
ITEM
: LEVEL DEPEND
Spec.
: Eliminate the detail signal from portion
B.
Note
. After this adjustment, be sure to perform 6-16. H/V
Ratio Adjustment, and 6-17. Detail Level Adjustment, in
that order.
6-14. Crispening Adjustment (4:3)
6-15. Level Depandent Adjustment (4:3)
4:3 mode
ON
ENC
CAM/ON
A
B
6-11

Hide quick links:

Advertisement

Table of Contents
loading