Error Code
Message Information
Action
VLT0225
Message
LCD Message
Details
Action
VLT0226
Message
LCD Message
Details
Action
VLT0227
Message
LCD Message
Details
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
1. Review system logs for power supply exceptions.
2. Re-configure the system to minimum configuration, inspect and
reinstall system cables.
3. If the issue persists, see
name > voltage is less than the lower critical
The memory module <
threshold.
number > < name > voltage is outside of range.
Memory module <
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
1. Review system logs for power supply exceptions.
2. Re-configure the system to minimum configuration, inspect and
reinstall system cables.
3. If the issue persists, see
name > voltage is greater than the upper
The memory module <
warning threshold.
number > < name > voltage is outside of range.
Memory module <
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
1. Review system logs for power supply exceptions.
2. Re-configure the system to minimum configuration, inspect and
reinstall system cables.
3. If the issue persists, see
name > voltage is greater than the upper critical
The memory module <
threshold.
number > < name > voltage is outside of range.
Memory module <
System hardware detected an over voltage or under voltage
condition.
Getting
Help.
Getting
Help.
Getting
Help.