System Layout 2 - Viessmann SCU224 User Manual

Temperature controller
Table of Contents

Advertisement

SCU224

System layout 2

The controller calculates the temperature difference bet-
ween collector sensor S1 and tank sensor S2. If the diffe-
rence is larger than or identical to the adjusted switch-on
temperature difference (DT O), the solar pump will be
operated by relay 1, and the tank will be loaded until the
switch-off temperature difference (DT F) or the maximum
tank temperature (S MX) is reached.
Arr 2
S1
R1
Display Channels
Channel
Description
x*
INIT
ODB initialization active
FLL
x*
ODB filling time active
x*
STAB
ODB stabilization in progress
COL
x
Temperature collector
TST1
x
Temperature tank 1 bottom
TSTT
x
Temperature tank 1 at the top
TST2
x
Temperature tank 2 bottom
n1 %
x
Pump speed R1
n2 %
x
Pump speed R2
h P1
x
Operating hours R1
h P2
x
Operating hours R2
TIME
x
Time
8
|
Heat exchange from tank 1 to tank 2 will be operated by
relay 2, if the temperature difference between sensors S3
and S4 is larger than or identical to the adjusted switch-on
temperature difference (DT3O), until the adjusted minimum
(MN3O) and maximum (MX3O) temperature thresholds of
the respective tanks are reached.
Tank 1
S3
S2
Tank 2
S4
R2
Terminal
-
-
-
S1
S2
S3
S4
R1
R2
R1
R2
-
Page
37
37
37
37
37
37
37
38
38
38
38
34

Hide quick links: